Installation
Utility Specications
PLUMBING SPECIFICATIONS
WATER
Water pressure 36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure
Water connection 3/4” garden hose cold water
Water quality requirements TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
pH: 7.0-8.5
DRAINAGE
Drain type Atmospheric Vented Drain
Drain connection 2.00” (50.8mm) Copper
Maximum water drain temperature 140ºF (60ºC)
RATINGS - GAS OVENS
Model Gas Type Input Voltage Phase Amps
BLCM-61G Natural 58,000 BTU 115 1 9
Propane 58,000 BTU 115 1 9
BLCM-101G Natural 87,000 BTU 115 1 9
Propane 87,000 BTU 115 1 9
BLCM-102G Natural 95,500 BTU 115 1 9
Propane 95,500 BTU 115 1 9
BLCM-62G Natural 81,800 BTU 115 1 9
Propane 81,800 BTU 115 1 9
BLCM-202G Natural 190,000 BTU 115 1 17
Propane 190,000 BTU 115 1 17