MODEL MNSD100TBA MNSD200TBA MNSD300TBA
BTU (available) 10,000 20,000 30,000
Ignition Electric Piezo Electric Piezo Electric Piezo
Gas Type Using Natural Gas Using Natural Gas Using Natural Gas
Pressure Regulator Setting 4" W.C. 4" W.C. 4" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 9" Maximum 9" Maximum 9"
Minimum 5" Minimum 5" Minimum 5"
Gas Type Using Propane Gas Using Propane Gas Using Propane Gas
Pressure Regulator Setting 9.5" W.C. 9.5" W.C. 9.5" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 14" Maximum 14" Maximum 14"
Minimum 11" Minimum 11" Minimum 11"
Heater Dimensions (HxWxD)
19
1
/
8
" × 14
1
/
8
" × 6
3
/
8
"
23
1
/
2
" × 19
1
/
4
" × 8" 23
1
/
2
" x 26
5
/
8
" x 8"
Carton Dimensions (HxWxD)
22 ×16
3
/
4
" × 8
1
/
8
"
25
3
/
4
" × 21
3
/
4
" × 9
1
/
4
"
25
3
/
4
" x 28
1
/
2
" x 9
1
/
4
"
Heater Weight 14.6 lbs 22.2 lbs 28.1 lbs
Shipping Weight 17.6 lbs 26.2 lbs 33.1 lbs
MODEL MNSD100HBA MNSD200TBA-BB MNSD300TBA-BB
BTU (available) 10,000 20,000 30,000
Ignition Electric Piezo Electric Piezo Electric Piezo
Gas Type Using Natural Gas Using Natural Gas Using Natural Gas
Pressure Regulator Setting 4" W.C. 4" W.C. 4" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 9" Maximum 9" Maximum 9"
Minimum 5" Minimum 5" Minimum 5"
Gas Type
Using Propane Gas
Using Propane Gas
Using Propane Gas
Pressure Regulator Setting 9.5" W.C. 9.5" W.C. 9.5" W.C.
Inlet Gas Pressure*
(inches of water)
Maximum 14" Maximum 14" Maximum 14"
Minimum 11" Minimum 11" Minimum 11"
Heater Dimensions (HxWxD)
19
1
/
8
" × 14
1
/
8
" × 6
3
/
8
"
23
1
/
2
" × 19
1
/
4
" × 8" 23
1
/
2
" x 26
5
/
8
" x 8"
Carton Dimensions (HxWxD)
22 ×16
3
/
4
" × 8
1
/
8
"
25
3
/
4
" × 21
3
/
4
" × 9
1
/
4
" 25
3
/
4
" x 28
1
/
2
" x 9
1
/
4
"
Heater Weight 14.1 lbs 25.1 lbs 31 lbs
Shipping Weight 17.1 lbs 29.1 lbs 36 lbs
SPECIFICATIONS
QUALIFIED INSTALLING AGENCY
Only a qualied agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term “qualied agency” means any
individual, rm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing, or
servicing equipment; that is experienced in
such work; that is familiar with all precautions
required; and that has complied with all the
requirement of the authority having jurisdiction.
Electrical Requirement for Blower Kit (if equipped)
Voltage • 120 VAC, 60 Hz