Do Not use an extension cord with
this dryer.
Do Not connect plug end of power sup-
ply cord into a live receptacle before
connecting power supply cord to dryer
terminal block.
STEP 1. Tum power supply off.
STEP 2. Remove hold-down screw
and terminal block cover.
Hold-down
screw
Terminalblockcover
STEP 3. Attach 3/4"U.L.-listed strain
relief (U.L. marking on strain relief) to
the hole below terminal block opening.
Put the power supply cord through
the strain relief.
STEP 4. Remove the center terminal
block screw. Remove the neutral grounding
wire (green/yellow wire) from external
grounding screw.
External ground
connector
Centersilver-colored
terminalblockscrew
©
STEP 5. Connect neutral grounding wire
and the neutra.I wire (white'.) of power
supply cord urLder the center screw of
terminal block
STEP 6. Co_nnect the other two insulated
wires to outer terminal block screws. Use
the same method described in STEP 4.
STEP 7. Conr_ect the green, grounding
wire from the power supply cord to the
external grourding conductor :screw.
Tighten all terminal block screws firmly.
STEP 8. Tighten the strain relief screws.
STEP 9. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down .';crew.
Centersilver-
External coloredterminal Whiteneutral
ground hlockscrew wire
connector
Greenwire
ofpowersupply
cordorbare
copperwire
!
(...-
0
Strainrelief
4-Wire Connection with
Frame-Grour_ding Conductor
Continue Installation on Page 16.