Restraining Device
Anchor Points
Grill Shutter
Pressure test point
NG Regulator
1/2” BSP
Internal Thread
Connection
Gas
Point
150mm
650mm
Gas Flo
w
The following table shows the supply and operating pressures for various supplies.
Gas type Natural gas Universal LPG Propane
Supply pressure at inlet to appliance regulator
(if fitted)
1.13 (kPa)
Minimum
2.75* (kPa) 2.75* (kPa)
Operate pressure at
appliance test point
1.00 (kPa) 2.75 (kPa) 2.75 (kPa)
* If the regulator is placed upstream of the cooker inlet, as is normal for cookers operating on LPG, then the supply pressure
and operating pressure are the same. The following table shows the injector sizes for each burner.
The following table shows the injector sizes for each burner.
Injector Natural gas Universal LPG Propane
Low heat burner 1.00 mm 0.55 mm 0.62 mm
Medium heat burner 1.35 mm 0.70 mm 0.82 mm
High heat burner 1.60 mm 0.90 mm 0.95 mm
Intense heat wok burner 1.75 mm 1.00 mm 1.00 mm
Grill–maininjector 1.50 mm 0.82 mm 0.82 mm
Oven–maininjector 1.60 mm 0.82 mm 0.95 mm
Oven–bypassscrew 0.73 mm 0.45 mm 0.45 mm
Checking pipe size
To work out a suitable pipe size for connection use the information in this table.
Natural gas Universal LPG Propane
Configuration
STD
Hob
WOK
Hob
Electric Grill
in Oven
STD
Hob
WOK
Hob
Electric Grill
in Oven
STD
Hob
WOK
Hob
Electric Grill
in Oven
Hourly gas
consumption for cooker
58.7MJ 60.4MJ 47.6MJ 45.9MJ 49.2MJ
36.9MJ
56.5MJ 58.3MJ
47.5MJ
Also use information about the length of the run, number of elbows,
tees and bends, the available service pressure and the supply
requirements.AS/NZS5601.1willhelpyouwiththismatter.
Operation on NG
• TheapplianceregulatorMUSTbeorientatedsothatthe
pressure nipple is accessible
• ThearrowshowingthedirectionofowMUSTbe
pointed correctly
• Theregulatorhasa½”BSPinternalthreadattheinletandoutlet.
Gas requirements
This appliance must be installed by an authorised person, according to all codes and regulations of:
• AS/NZS5601.1(particularattentiontoclause6.10.1andgure6.3onpage97,andclause6.10.1.11)
• Localgasttingregulations,municipalbuildingcodesandotherstatutoryregulations.
The cookers come in three gas types:
Naturalgas,PropaneandUniversalLPG.IfthecookerisrequiredtouseULPG,aconversionkitcanbeobtainedby
contacting the Customer Care Centre for details. Before installation, check that the cooker is suitable for the gas supply by looking
at the data plate behind the bottom of the oven door.
installation
Chef 540 Upright Cooker INSTALLATION 21