Seiki SC-5100AU6A 5.1KW Reverse Cycle Split System Inverter Air Conditioner

User Manual - Page 7

For SC-5100AU6A.

PDF File Manual, 20 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
7
INSTALLATION OF INDOOR UNIT
1. Installation of Wall Mounting Plate
• Make sure the plate is completely level by using a spirit level, if mounting plate is
slanted it can hinder the smooth discharge of the condensed water.
• Mark and drill mounting holes corresponding with the mounting holes in the
mounting plate.
• Fix the wall mounting plate firmly on the wall with screws.
The method of fixing is not to depend on the use of adhesives since they are not considered
to be a reliable fixing means. *(Mounting hardware not supplied)
2. ACCESS TO PIPING
• Drill holes at places slightly below the wall mounting plate corresponding with where the
piping and drain outlet exit the indoor unit with hole diameter of 65mm starting from the
inside wall, and make the outside wall 5-10mm lower so the water can smoothly flow out.
• Cut the wall penetrating pipe to correct length according to the thickness of the wall and
add 5mm extra length longer then the wall thickness and insert the pipe as indicated.
3. INSTALLATION OF DRAIN PIPE
• Install the piplines of the indoor unit in accordance with the wall hole.
Wrap tightly the drain pipe and the pipelines with trap, Make sure the drain pipe is
underneath the pipelines of indoor unit.