Installation Manual 23
ENGLISH
Installation
Thermostat cable
Wired remote
controller cable
Lock nut
Conduit
mounting plate
1/2 inch(21.3 mm)
Conduit
Connecting cable
2. Install conduit to the wiring knockouts.
Connect connecting / wired remote controller cable or Thermostat cable to terminal block through
the wiring knockouts.
:
1. Use connection cable NRTL(UL, ETL, CAS…) listed and stranded copper(4) THHN conductors,
sunlight (UV) resistant ROHS compliant PVC jacket 600 V direct burial listed, approved for wet
conditions. Temperature rated for -20 ℃(-4 ℉) to 90 ℃(194 ℉). And this cable should be enclosed
in conduit.
WARNING
• Be sure to comply with local and national codes while running the wire from the indoor unit to the outdoor
unit(size of wire and wiring method, etc).
• Every wire must be connected firmly.
• No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.
• The communication wirings of air conditioner should be separate and isolated from external
device’s electric wiring such as computers, elevator, radio & Television broadcasting facilities, as
well as medical imaging offices.
HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)
NOTE : Openings where field wiring enters the cabinet must be completely sealed.