60 - CLEANING AND MAINTENANCE 91477A233/B
Special cleaning functions
1. Turn the function knob until the following text
appears on the display.
2. Press the temperature knob to access the
special functions menu.
Vapor Clean (on some models only)
Preliminary operations
Before starting the Vapor C lean cycle:
Completely remove all accessories from
inside the oven.
Remove the temperature probe, if present.
Remove the self-cleaning panels, if present.
Pour approx. 120 cc of water onto the floor
of the oven. Make sure it does not overflow
out of the cavity.
Spray a water and washing up liquid
solution inside the oven using a spray
nozzle. Direct the spray towards the side
walls, upwards, downwards and towards
the deflector.
Close the door.
During the assisted cleaning cycle, wash the
self-cleaning panels (where fitted), which
were previously removed, separately in
warm water and a small amount of
detergent.
Vapor Clean cycle setting
3. After having accessed the special functions
menu, turn the temperature knob to select
the Vapor Clean function.
4. Press the temperature knob to confirm the
function.
5. Wait 3 seconds before starting the function.
6. At the end of the Vapor Clean cycle,
appears on the display and a
buzzer will sound that can be deactivated
See General safety instructions.
The Vapor Clean function is an assisted
cleaning procedure that facilitates the
removal of dirt. Thanks to this process, it
is possible to clean the inside of the
oven very easily. The dirt residues are
softened by the heat and water vapour
for easier removal afterwards.
We recommend spraying approx. 20
times at the most.
Do not spray the deflector if it has a self-
cleaning coating.
If the internal temperature is greater
than the one required, the function will
be stopped immediately and the
following message appears on the
display:
Let the appliance cool down before
activating the function.
The duration and temperature
parameters cannot be changed by the
user.