Connect the neutral (white) conductor of the cord to the center (silver colored) post of the
terminal b!ock. Connect the grounding (green) wire of the cord to the terminal block support
using the ground strap screw.
Connect the red and black wires of the cord to the outer posts of the terminal block.
Be sure the terminal block nuts are on tight. Secure tile power cord in position. Tighten the
strain relief screw(s) in order to clamp the strain relief to the cord.
Replace the terminal block cover.
WARNING: If converting from 4-wire electrical systems to 3-wire, the ground strap must
be reconnected to terminal b!ock support to ground the dryer flame to the neutral conductor