Primary Area:
Condensation from the
chassis collects in the
sleeve in this area. The
Primary Area is the
preferred installation
location.
PXDR10 DRAIN KIT
When using an external drain system, the
condensate is removed through either of two
drain holes on the back of the wall sleeve.
Select the drain hole which best meets your
drainage situation and install the drain kit. Seal
off the other with a cover plate.
Place the drain tube through the gasket and
the mounting plate with the flange toward the
wall sleeve.
Attach the drain tube assembly to one of the two
drain holes at the rear of the wall sleeve. The
large flange on the mounting plate is positioned
at the bottom of the sleeve facing toward the
sleeve. When the drain tube is positioned at the
desired angle, tighten the screws.
Back
of wall
sleeve
1/2" O.D. Tube
Plate
Foam Gasket
CAUTION:
Bodily injury can be caused by louvers
falling from a building during installation.
It is recommended that a safety line be
attached to the louver and an anchor point
inside the building during installation.
Installation
1. Screw a threaded metal stud into each
of the holes at the four corners of the
louver.
2.
From inside the building, grasp the
louver at the vertical supports and
maneuver the louver through the wall
sleeve. Pull towards you until the
threaded studs are inserted into the
four holes of the wall sleeve.
3. While holding the louver with one hand,
start washers and nuts on each of the
four studs. Tighten the nuts securely.
6