Kenmore 79691582410 dryer

User Manual - Page 17

For 79691582410.

PDF File Manual, 72 pages, Download pdf file

Loading ...
Loading ...
Loading ...
FINAL iNSTALLATION CHECK
Once you have completed the _nstallation of the dryer
and i? is in its final location, confirm proper operation
with the following steps and tests.
is gas turned on? (Gas models only)
Is dryer plugged in? Dryer should always be
plugged into the proper outlet.
Gas dryer should use a
120-VAC, 60-Hz. grounded
3-prong outlet.
Electric dryer should use a
4-wire connection which is
required for a!l mobile
and manufactured home
installations, as well as all new
construction after
January 1, 1996.
-- OR --
A 3-wire connection,
NOTE: A 3-wire connection
is NOT permitted on new
construction after
January 1, 1996.
Testing Dryer Heating
Close the dryer door.
Pressthe POWER button to turn the dryer on.
Turn the cycle selector knob to Normal drying cycle.
O Pressthe START/PAUSE to start the dryer. After three
minutes_ open the dryer door and check that the air
inside is warm.
NOTE: If the air inside the dryer is not warm after
three minutes, there may be air in the gas supply line to
the dryer, and the gas igniter may turn off: before the
main burner ignites. When this happens, the igniter will
continue to attempt main burner ignition until all air is
purged from the line. Once ignition occurs, the air inside
the dryer will become warm.
Checking Ven|ing
Vent ductwork should be checked for lint buildup
and cleaned at least once per year. If any noticeable
reduction in drying performance occurs, check duct for
obstructions and blockages.
is the dryer transition duct from dryer to wall
connected? Make sure the transition duct behind the
dryer is properly connected and is not crushed or
damaged,
msdryer level? Once the dryer is in its final location,
recheck the dryer to be sure it is level. Make sure it is
level front to back and side to side, and that all four
levelin_ feet rest firmly on the floor.
Is the dryer heating normally? Perform the following
dryer heating test.
17
Loading ...
Loading ...
Loading ...