Dacor DWR30M977WS

User Manual - Page 15

For DWR30M977WS.

PDF File Manual, 24 pages, Read Online | Download pdf file

DWR30M977WS photo
Loading ...
Loading ...
Loading ...
English 15
Installation instructions
Electrical connection
WARNING
Electrical Shock Hazard
IMPORTANT: The unit has a three-prong, grounding plug to prevent possible electric
shock. If a two-prong electrical outlet is available, the owner must have it replaced
with a dedicated, properly grounded, three-prong electrical outlet. To avoid an
electric shock hazard, DO NOT:
remove the cord's third (ground) prong.
use an adapter plug.
use a worn/damaged cord.
immerse the cord or plug in liquid.
Connect the appliance to an extension cord.
NOTE
You should not use a ground fault interrupter (GFI).
Three-prong plug
Three-prong
grounded outlet
Minimum ambient operating
temperature: 32°F (0°C).
The correct voltage, frequency, and
amperage (see the product data label,
interior drawer face) must be supplied
to the outlet from a grounded, single-
phase circuit protected by a properly
sized circuit breaker or time-delay fuse.
The power-supply requirements on pg.
16 are for reference only. If they do not
agree with those on the data label,
follow the data on the label.