10
Installing the CO
2
cylinder
1. Ensure all connections between the
regulator and unit are secure.
Position the regulator on top of the CO
2
cylinder.
2. Tighten the bottle by rotating anti-clockwise.
CO
2
will escape while you are turning the
bottle. Continue to turn the bottle to form
a seal with the regulator.
3. Open the pressure regulator by turning the
black knob clockwise.
Set the initial pressure to around 3 Bar.
Turn on the unit power and water supply.
Wait for the unit to come back to
temperature.
4. Check bottle and connections for leaks using
soapy water to test for bubbles.
NOTE: the ¼" tube and pushfit fittings may
settle when the pressure is turned on.
5. Increase the pressure to set your level of
carbonation.
Initial set point may vary once the unit is
running, you may need to reset the pressure
once the system has stabilised.
WARNING: do not set the pressure above 5 bar.