Installation
*INSTALLATION*
45
In recirculation mode, the silencer
needs to be positioned between the
exhaust socket and the directional
unit. Check that there is sufficient
space.
Electrical connection
Refer to the notes in “Electrical
connection” and “Warnings and
safety notes” before connecting to
the power supply.
The connection data (voltage,
frequency) on the data plate must
match the data of the mains power
supply. The position of the data plate is
explained in the “Service” chapter.
The cooker hood is equipped with a
power cable and a safety plug.
The connection must be made via a
socket which remains accessible after
the cooker hood has been installed. If
the socket is no longer accessible after
installation or if you are using a hard-
wired connection, there must be a
suitable means of disconnection for all
poles in the household electrical system
which meets the requirements of
overvoltage category III.
Safety can be increased by fitting the
appliance with a residual current
device.
Only qualified electricians are permitted
to carry out work on the household
electrical system.
This appliance must be earthed.