Operating Instructions and Owner’s ManualMr. Heater, Inc.| Forced Air Propane Construction Heater
SPECIFICATIONS
Model: MH60QFAV MH85QFAV MH125QFAV
Rating:BTU 30,000-60,000Btu/Hr 50,000-85,000Btu/Hr 75,000-125,000Btu/Hr
Kilowatts (8.8-17.5kW) (14.6–25.0kW) (21.9--36.6kW)
FuelConsumption: 1.4-2.8lbs/hr 2.3–3.9lbs/hr 3.5--5.8lbs/hr
(0.64-1.27kg/hr) (1.04–1.77kg/hr) (1.56--2.63kg/hr)
GasSupplyPressure
(toregulator):
Max.BottlePressure
Min.20psi(137.kPa
Max.BottlePressure
Min.20psi(137.kPa
Max.BottlePressure
Min.20psi(137.kPa
GasSupplyPressure
(Regulatorout):
20psi(137.9kPa) 20psi(137.9kPa) 20psi(137.9kPa)
ElectricalInput
115V,60Hz,1Ø,2A
Min.OperatingVoltage:100V
115V,60Hz,1Ø,2A
Min.OperatingVoltage:100V
115V,60Hz,1Ø,2A
Min.OperatingVoltage:100V
230Watts(W) 230Watts(W) 230Watts(W)
HighTemperatureControl: 240°F(116°C) 240°F(116°C) 240°F(116°C)
Ignition AutoSpark/ManualValve AutoSpark/ManualValve AutoSpark/ManualValve
**Eachheaterispackagedwitha10'longhosewithregulator**
OPERATING PRECAUTIONS
Thisisapropane,direct-fired,forcedairheater.It'sintendeduse
is primarily temporary heating of buildings under construction,
alteration or repair.
Propaneisheavierthanair.Ifpropaneleaksfromaconnectionor
fitting,itsinkstothefloor,collectingtherewiththesurrounding
air,formingapotentiallyexplosivemixture.Obviously,propane
leaksshouldbeavoided,sosetupthepropanesupplywith
utmostcare.ReadenclosedOdorFadeandPropaneSheetfor
additionalinformationaboutdetectingpropaneleaks.Leakcheck
new connections or reconnections with a soap and water solution
andfollowallconnectioninstructionsherein.Also,askyour
propanedealerforadviceonthepropaneapplicationandsupply
installationandaskhimtocheckitifthereareanyquestions.
Thisheaterwasdesignedandcertifiedforuseasaconstruction
heaterinaccordancewithANSIZ83.7/CGA2.14.Checkwith
yourlocalfiresafetyauthorityifyouhaveanyquestionsabout
yourapplications.Otherstandardsgoverntheuseoffuelgases
andheatproducingproductsinspecificapplications.Yourlocal
authoritycanadviseyouaboutthese.
Direct-Firedmeansthatallofthecombustionproductsenterthe
heatedspace.Eventhoughthisheateroperatesverycloseto100
percent combustion efficiency, it still produces small amounts of
carbonmonoxide.Carbonmonoxide(calledCO)istoxic.Wecan
toleratesmallamountsbutnotalot.COcanbuildupinaheated
spaceandfailuretoprovideadequateventilationcouldresultin
death.
Thesymptomsofinadequateventilationare:
•headache
•dizziness
•burningeyesandnose
•nausea
•drymouthorsorethroat
So,besuretofollowadviceaboutventilationintheseoperating
instructions.
ForcedAirmeansthatablowerorfanpushestheairthroughthe
heater. Proper combustion depends upon this air flow; therefore,
theheatermustnotberevised,modifiedoroperatedwith
partsremovedormissing.Likewise,safetysystemsmustnotbe
circumventedormodifiedinordertooperatetheheater.
Whentheheateristobeoperatedinthepresenceofotherpeople
theuserisresponsibleforproperlyacquaintingthosepresent
withthesafetyprecautionsandinstructions,andofthehazards
involved.
CAUTION: For use with Propane Only
NOT FOR USE WITH DUCT WORK
Model: Length(in) Width(in) Height(in) Weight(LBS)
MH60QFAV 19.75 11. 5 0 14.25 19.00
MH85QFAV 18.50 11. 5 0 14.00 19.00
MH125QFAV 21. 25 11. 7 5 16.00 22.15
DIMENSIONS