MAINTENANCE 39
Application GuidelinesANater Supply Parameters
Service Flow 0.5 gpm (1.9 Ipm)
Water Supply Potable Water
Water Pressure 20 -120 psi (138 - 827 kPa)
Water Temperature 33°F - 100°F (0.6°C - 38°C)
It is essential that the manufacturer's recommended instal-
lation, maintenance and filter replacement requirements be
carried out for the product to perform as advertised.
-_ NOTE
While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge: ADO36006101
For estimated costs of replacement elements
please call USA 1-800-243-0000
CANADA 1-888-LGCANADA (24 hours per day/7 days per
week) or visit our website at www.lg.com
3M is a trademark of 3M Company.
NSF is a trademark of NSF International.
© 2009 3M Company. All rights reserved.
WARNING
To reduce the risk associated with choking:
Do not allow children under 3 years of age to have
access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of
contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may
be used on disinfected water that may contain filterable
cysts. EPA Establishment # 070B9B-MEX-001
CAUTION _,
To reducethe riskassociatedwithpropertydamage due to
water leakage:
Read and follow,Use Instructionsbeforeinstallationand
use ofthissystem,
Installationand use MUST comply withallstateand local
plumbingcodes,
Do notinstallifwater pressureexceeds 120 psi(827
kPa). If your water pressure exceeds 80 psi, you must
install a pressure limiting valve. Contact a plumbing pro-
fessional if you are uncertain how to check your water
pressure.
Do not install where water hammer conditions may oc-
cur. If water hammer conditions exist you must install a
water hammer arrester. Contact a plumbing professional
if you uncertain how to check for this condition.
Do not install on hot water supply lines. The maximum
operating water temperature of this filter system is
100°F (37.8°C).
Protect filter from freezing. Drain filter when tempera-
tures drop below 40°F (4.4°C).
The disposable filter cartridge must be replaced every 6
months, at the rated capacity or if a noticeable reduction
in flow rate occurs.
Protect from freezing, remove filter cartridge when tem-
peratures are expected to drop below 330 E
Do not install systems in areas where ambient
temperatures may go above 1100 F (43.30 C).
Where a backflow prevention device is installed on a
water system, a device for controlling pressure due to
thermal expansion must be installed.
Ensure all tubing and fittings are secure and free of leaks.
Manufactured for LG®Electronics by CUNO
Incorporated 400 Research Parkway Meriden,
CT 06450 U.S.A Worldwide: 203-237-5541