Summit PTHC155GCSSLHD 24" Wide Blanket Warmer

User Manual - Page 5

For PTHC155GCSSLHD. Also, The document are for others Summit models: PTHC65G*, PTHC125G*, PTHC155G*

PDF File Manual, 20 pages, Read Online | Download pdf file

PTHC155GCSSLHD photo
Loading ...
Loading ...
Loading ...
5!
!
Reversing the Door Swing (Only applicable to the PTH65G Series)
The door of the warming cabinet can be hinged on either side so that the door swing can be suited
to the location of the installation. In order to reverse the position of the door hinges, refer to the
disassembly diagrams below this procedure.
1. Lay the warming cabinet onto its back side, being careful to set it onto a blanket or another soft
surface.
2. Remove the screws holding the bottom hinge, and remove the hinge.
3. Slide the door downward, being careful to remove the door pin attaching the door to the upper
hinge.
4. Set the door aside.
5. Remove the screws holding the upper hinge to the warming cabinet.
6. Remove the hinge covers from the opposite side of the cabinet.
7. Move the upper hinge to the opposite of the cabinet, and tighten with screws.
8. Replace the door pin on the opposite side of the door, and slide the door pin into the upper
hinge.
9. Rest the door against the warming cabinet, and attach the lower hinge to the cabinet and door.
10. If the door is not hanging straight, loosen the top hinge, adjust the door until it is straight and
retighten the screws.
Installing the Door Handle
This appliance may include a stainless-steel door handle that is not required to operate the unit. To
install the handle, follow these steps:
1. Pull away the door gasket in area where the handle is to be installed. The gasket is easily
displaced by the hand. No tools are necessary.
2. Using a flathead screwdriver, remove the two pre-installed decorative plugs from the back of the
door. Save the decorative plugs for future use.
3. Insert the two Phillips head handle screws through the gasket side of the door frame until the
screws pass through the door frame.
4. Align the handle with the screws installed in Step 3. Tighten the screws using the Phillips head
screwdriver until the handle is both flush and secured tightly against the door frame. DO NOT
over-tighten, as this will cause damage to the handle assembly.
5. Replace the door gasket to its original position.
Loading ...
Loading ...
Loading ...