J. Detailed Component Operating
Instructions - Intellire™ Touch
IFT-ECM Detailed Operating Instruction
Figure 3.6. IFT-ECM
3 POSITION SWITCH
TOP VIEW
LED INDICATOR
DANGER
Risk of Explosion
DO NOT cycle the ON/OFF/REM selector
switch more than one time within a ve minute
period. Gas may accumulate in rebox. Call
a qualied service technician.
DANGER
Risk of Explosion
DO NOT cycle the ON/OFF/REM selector
switch more than one time within a ve minute
period. Gas may accumulate in rebox. Call
a qualied service technician.
4. An IFT-ECM reset is required if the module is in a
lock-out condition. When this occurs, the appliance
is shut down and the IFT-ECM status indicator LED
will be blinking a RED/GREEN error code along with a
one-time audible double- beep. If the IFT-ECM is in a
lock-out condition, refer to the troubleshooting chart to
interpret the error code and take corrective action as
required. To reset the IFT-ECM after a lock-out error:
1. The Electronic Control Module (IFT-ECM) has a
three-position ON/OFF/REMOTE selector switch
that must be set for proper operation. See Figure
3.6. When changing switch positions,it is important
to pause in each position for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands
from a wired wall switch, IFT-RC150 or IFT-RC400
remote controls. The unit should be in the OFF
position during installation, service, backup battery
installation, fuel conversion and to reset the IFT-
ECM in the event the system goes into a LOCK-
OUT mode as the result of a system error. When
switched to the OFF position while the appliance is
operating, the system will shut down.
ON Position:
The appliance will ignite and run continuously at
the HI ame setting. No adjustment in ame height
is possible.
The IFT-ECM has a safety feature that will
automatically shut down the replace after
9 hours of continuous operation in the ON
position.
Remote Position:
The remote position allows operation of the
appliance from a wired wall switch, IFT-RC400 or
IFT-RC150 remote controls. The IFT-ECM switch
must be in this position to pair the IFT-ECM with the
IFT-ACM (if installed), and/or IFT-RC400 and IFT-
RC150 remote controls. See the IFT-RC400 or IFT-
RC150 installation manual for detailed instructions
on pairing the IFT-ECM with the remote controls.
After successfully pairing a IFT-RC400, all installed
accessories can be controlled by the IFT-RC400
(see IFT-RC400 user manual). The RC150 allows
the user to turn ON/OFF the ame in the appliance
and activate the Cold Climate mode if desired. The
IFT-ECM has a safety feature that will automatically
shut down the replace after 9 hours of continuous
operation without receiving a command from the
IFT-RC400 or IFT-RC150.
2. If multiple control options are installed, the IFT-ECM
will respond to the last command from the wired wall
switch, IFT-RC400 or IFT-RC150. The wired wall
switch is NOT available if a Power Vent is used.
3. The Pilot button on the IFT-ECM activates the Cold
Climate function of the replace. This function lights
the pilot ame ONLY to provide enough heat in the
rebox to reduce condensation in cool, high humidity
ambient conditions. To activate the Cold Climate
press and hold the Pilot button for one second and
release. The IFT-ECM will ash two green LED blinks,
beep twice and light and rectify the pilot ame when
pressed to activate. To turn off Cold Climate, press
and hold the Pilot button for one second and release.
The IFT-ECM will ash one green LED blink, beep once
and shut down the pilot ame. If remote controls are
paired with the IFT-ECM, this feature can also be
activated with the IFT-RC400 and/or IFT-RC150.
CAUTION! Risk of burns! Appliance surfaces are hot
when operating and during cool down. Use care and
wear gloves when opening the front and accessing com-
ponents inside the appliance.
- Be aware the appliance may be HOT, use
care in accessing the IFT-ECM.
- Set the IFT-ECM 3-position selector switch to
OFF position.
The IFT-RC400 and IFT-RC150 remotes are an option
for the LCOR-DV36IN/RCOR-DV36IN models.