Planning the Installation
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
G
10" (25.4 cm) min.
to combustible side
walls above the range
(on both sides)
non-combustible
rear wall (recommended)
H
Backsplash
3/8" (1.0 cm)
min. for downdraft cap
clearance
J
Note 2
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer,
but cabinet face MUST NOT extend further than rear of
front panel, see product dimensions.
3
Consult the local code for exact location requirements.
1
Vertical from range grate level to combustible overhead
surface; if installing an overhead vent hood, also check
hood specifications for minimum required clearances.
4
Vertical from grate level to combustible surface.
Non-combustible
surface along back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
13” (33.0 cm)
max.
5
15” (38.1 cm)
min.
4, 5
5
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
Suggested
location of
utilities
3
Grate
level
Cutouts & Tolerances
F G
36” (91.4 cm)*
30” (76.2 cm)**
30” (76.2 cm)**
* Recommended length
** Minimum length
H J
27 1/2” (69.9 cm) 3 1/2”