Ovation MH-901DA-BLK Air Inn s Cool Mist Digital Humidifier - Black

User Manual - Page 8

For MH-901DA-BLK.

PDF File Manual, 12 pages, Read Online | Download pdf file

MH-901DA-BLK photo
Loading ...
Loading ...
Loading ...
Weekly Cleaning & Care
WARNING: Before cleaning always turn power o and unplug the unit from outlet.
WARNING: DO NOT rinse Base under faucet. To clean, wipe the Base with a soft cloth.
WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep water away
from the Air Outlet.
WARNING: DO NOT tamper with the Water Sensor.
About White Dust -Use of high-mineral content water may cause a white mineral residue to accumulate on room surfaces
near the humidier. The mineral residue is commonly referred to as “White Dust”. The higher the mineral content (the harder
your water), the greater the potential for White Dust. The White Dust is not caused by a defect in the humidier, but is due only
to minerals suspended in the water from your tap.
WARNING: If you have hard tap water STOP using tap water and use
ONLY ltered, distilled, cold boiled or bottled water to minimize the White Dust residue or visit our website to purchase our
Humidier Demineralization (hard water) Filters (www.Air-Innovations.com).
Tank Cleaning - Unplug unit & remove the Mist Nozzle from the top of the Water Tank then remove the Water Tank from the
unit. Turn the tank upside down and drain any water from the tank. Wipe the tank with a soft damp cloth then rinse it with
warm water inside and out.
Base Cleaning
1. Unplug unit.
2. Use enclosed Silicone Plug and place over water inlet (see below).
3. Clean the Base by gently wiping with a soft damp cloth .
White Dust Cleaning - If mineral deposits “White Dust” are evident
around the Ultrasonic Nebulizer
a
and Water Sensor, clean these surfaces
with a soft cloth and a small amount of undiluted white vinegar.
If necessary, mix a solution of 50% white vinegar and 50% water
and ll the Base with enough solution to cover the Ultrasonic
Nebulizer
a
. Allow it to soak for an hour and then use the provided
brush to gently loosen buildup on the Ultrasonic Nebulizer
b
.
Put 1 cup of water in the Base and wipe clean with a soft cloth.
WARNING: DO NOT rinse Base under faucet.
WARNING: When emptying the Water Reservoir in the Base,
make sure that the water is poured away from the Air Outlet
c
.
If water is poured into the outlet it may damage the humidier.
Ceramic Water Filter Cleaning
1. Unplug unit and empty water from Tank.
2. Remove all jewelry to avoid damaging the Tank.
3. Lift Water Tank Lid and place hand inside the Tank and moderately grasp the Ceramic Water Filter and unscrew by twisting
counterclockwise
d
. Rinse the Ceramic Filter with running tap water for approx 20-30 seconds
e
. Then replace lter
inside Water Tank by twisting clockwise until secure
f
.
Surface Cleaning - Clean all surfaces of the unit with a clean damp soft cloth
.
6
1. Follow all cleaning instructions prior to storage.
2. Dry all parts, including the inside of the Water Tank.
WARNING: NEVER
leave water inside the tank for
several days.
3. Preferably store in its original box, in a dry place away from high temperatures.
4. Follow all cleaning instructions after long periods of storage.
Storage
a
b
c
d
e
f
Using Silicone Plug
Please apply the enclosed plug during cleaning ONLY in order to avoid
debris from entering the pump. NOTE: the plug MUST be REMOVED
for normal operation and lling.
Loading ...
Loading ...
Loading ...