24 Value Series Manual
Technical Data
Specicaons
* Minimum ow may vary slightly depending on the temperature seng and the inlet water temperature.
Minimum acvaon ow is 0.4 GPM (1.5 L/min).
Our products are connually being updated and improved; therefore, specicaons are subject to change without prior
noce.
The maximum inlet gas pressure must not exceed the value specied by the manufacturer. The minimum value listed is for
the purpose of input adjustment.
V65i V75i V94Xi V94i V65e V75e V94e
Minimum Gas Consumpon Btu/h
10,300
Maximum Gas Consumpon Btu/h
150,000 180,000 192,000 199,000 150,000 180,000 199,000
Hot water capacity (Min - Max) *
0.26 - 6.6 GPM
(1.0 - 25.0 L/min)
0.26 - 7.5 GPM
(1.0 - 28.5 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
0.26 - 6.6 GPM
(1.0 - 25.0 L/min)
0.26 - 7.5 GPM
(1.0 - 28.5 L/min)
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
Temperature Seng (no controller)
120° F (49° C) or 140° F (60° C)
Maximum Temp Seng (residenal)
Selectable at 120° F (49° C) or at 140° F (60° C)
Minimum Temperature Seng
98° F (37° C)
Weight
45.6 lb
(20.7 kg)
45.6 lb
(20.7 kg)
46.3 lb
(21.0 kg)
46.3 lb
(21.0 kg)
43.6 lb
(19.8 kg)
43.6 lb
(19.8 kg)
44.3 lb
(20.1 kg)
Noise level
49 dB (excluding start up or shutdown)
Electrical Data
Normal
76 W 76 W 97 W 97 W 57 W 57 W 65 W
Standby
2 W
An-frost
Protecon
120 W 104 W
Max Current
4 A
Fuse
10 A
By-Pass Control
Fixed Fixed Electronic Electronic Fixed Fixed Electronic
Gas Supply
Pressure
Natural Gas
4.0 - 10.5 inch W.C.
Propane
8.0 - 13.5 inch W.C.
Type of Appliance
Direct Vent, Tankless, Temperature controlled connuous ow gas hot water system
Connecons
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignion System
Direct Electronic Ignion
Electric Connecons
Appliance: AC 120 Volts, 60Hz.
Temperature Controller: DC 12 Volts (Digital)
Water Temperature Control
Simulaon Feedforward and Feedback
Water Supply Pressure
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Temperature Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
Cered for installaon in
manufactured (mobile) homes
Yes
Complies with South Coast Air Quality
Management District 14 ng/J or 20
ppm NOx emission levels
Yes Yes Yes No Yes Yes Yes