INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
32
470
350
675
A
315
All dimensions in millimetres
Gas inlet
Flexible hose
PipeworkPipework
Flexible hose
Fitting the Restraining Chain
The restraining chain MUST be tted.
The length of chain between the appliance and the wall xing
should prevent strain on the gas and electricity connections,
but still allow access to unhook the chain when the cooker is
pull forward.
Measure the length of chain required. Use the clamp supplied
to clamp onto the gas pipe (Fig. 11.9). Fix the supplied hook
securely to the wall.
Gas Connection
Must be in accordance with the relevant standards.
The gas supply needs to terminate with a down-facing
threaded tting ½” connection.
The inlet connector is located just below the hotplate level at
the rear of the cooker.
Because the height of the cooker can be adjusted and
each connection is dierent it is dicult to give precise
dimensions. Ideally, the house supply connection should be
in the shaded area A’ (Fig. 11.11).
Means of isolation must be provided at the supply point by
either an approved quick-connect device or a Type 1 manual
shut-o valve.
The hose should be tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in
a ‘U’ shape (Fig. 11.11).
A exible connection is supplied with the cooker. If it is
necessary to use another hose it must be to AS 1869 Class B
and be suitable for your gas type.
If in doubt contact your supplier. Screw connect the threaded
end of the hose into the gas inlet.
After completing the gas connection, check the cooker is gas
sound with a pressure test. When checking for gas leaks do
not use washing up liquid – this can corrode. Use a product
specically manufactured for leak detection.
Natural Gas
The adjustable spring loaded gas pressure regulator is
present to give a nominal pressure of 1 kPa on Natural gas.
Connect to the Rp ½ inlet on the underside of the pressure
regulator.
Propane
This cooker is supplied ready for use on Natural gas. A
conversion kit for Propane as is supplied with the cooker –
see the Conversion to Propane Gas’ section.
A – Position of gas supply connector
ArtNo.011-0007 - Restraining chain (AUS)
Restraining
chain
Fig. 11.9
Fig. 11.10
Fig. 11.11