Loading ...
Loading ...
Loading ...
Section 4 - ADJUSTMENTS & REPAIR
WARNING
The electrolyte (acid) produces a highly explosive gas.
Keep all sparks, flame and fire away from area when
charging battery or when handling electrolyte or battery.
Electrolyte (acid) is a highly corrosive liquid. Wear eye
protection. Wash affected areas immediately after
having eye or skin contact with electrolyte (acid). Battery
acid is corrosive. Rinse empty acid containers with
water and mutilate before discarding. If acid is spilled on
battery, bench, or clothing, etc., Flush with clear water
and neutralize with baking soda. DO NOT attempt to
charge battery while installed on the YARD CRUISER.
DO NOT use "BOOST" chargers on the battery.
IMPORTANT: 3/16" above cell plates is the recommended
level. DO NOT place anything in battery other than specified
electrolyte.
VV,ARNING
DO NOT OVERFILL. DO NOT attempt to chargeI
battery while installed on the Yard Cruiser. DO NOT
use "BOOST" chargers on the battery. I
5. Slow charge the battery at 1 amp for 2 hours to
bring the battery to full charge.
6. After charging, check level of electrolyte and add
as needed to bring level to 3/16" above cell plates.
7. Reinstall cell caps.
8. Install battery into power unit. Connect over flow
tube.
9. Connect positive (+) cable (red) first, from wiring
harness to the positive terminal (+) on battery using
bolt and nut provided in hardware bag. Connect
negative (-) cable (black) last, to negative terminal
(-) on battery using bolt and nut. Apply a small
amount of grease over terminals to prevent
corrosion.
Shield the positive terminal with terminal
located on battery harness. This prevents
from touching the positive terminal, which
cause sparks.
4.4.6. BATTERY TESTING
There are two types of battery tests: Unloaded and
Loaded. The unloaded test is the procedure that will
be discussed. It's the simplest and most commonly
used. An unloaded test is made on a battery without
discharging current. To perform unloaded testing,
check charge condition using either a hydrometer or
voltmeter.
1. Using a voltmeter, voltage readings appear
instantly to show the state of charge. Remember to
hook the positive lead to the battery's positive
terminal, and the negative lead to the negative
terminal.
2. A hydrometer measures the specific gravity of
each cell. The specific gravity tells the degree of
charge; generally, a specific gravity of about 1.265
to 1.280 indicates full charge. A reading of 1.230 to
1.260 indicates the battery should be charged. The
Battery Condition chart below shows the charge
level as measured by syringe float hydrometer,
digital voltmeter and five ball hydrometer.
State of Charge
100% Charged w/Sulfate Stop
100% Charged
75% Charged
50% Charged
25% Charged
0% Charged
Battery Condition
Syringe Hydrometer
1.280
1.265
1.210
1.160
1.120
Less than 1.100
Chart
Digital Voltmeter
12.80v
12.60v
12.40v
12.10v
11.90v
Less than 11.80v
Five Ball Hydrometer
Five Balls Floating
Four Balls Floating
Three Balls Floating
Two Balls Floating
One Ball Floating
Zero Balls Floating
22
Loading ...
Loading ...
Loading ...