Kenmore 79558826900 Elite refrigerator

User Manual - Page 19

For 79558826900.

PDF File Manual, 31 pages, Read Online | Download pdf file

79558826900 photo
Loading ...
Loading ...
Loading ...
Performance Data Sheet
Models Number 5231JA2002B-S
Use with replacement cartridge 5231JA2002B
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSl 42.
i
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction
of Chlorine Taste and Odor and Nomina! Particulate Class Ill.
1
Capacity: 500 gal (1,892 L)
Substance Average Influent Challenge Avg. Product Average NSF % reduction req.
Infiuent Concentration. Units Water % or Max. permissible product
Concentration apply to each row Concentration Reduction water concentration
Nominal Particulate
Class I Particle size: >0.5 to<lum 24,333 At least 10,000 particles/ml 915 96 >_ 85%
Chlorine taste and odor > 50%
ClassIII 1.9 2.0 mg/L +_10% 0.07 96.4 _
Notethat while the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines/Water Supply Parameters
Service flow 0.5 gpm ( 1.89 ipm)
Water pressure 20- 125 psi (138- 862 kPa)
Water temperature 33°F - 100° F (0.6°C - 38°C)
[] WARNING
Toreducethe riskassociatedwith ingestionof contaminantsdueto usewith
waterthatis microbiologicallyunsafeor ofunknownquality.
Do notusewith waterthat is microbiologicallyunsafeor of unknownquality
withoutadequatedisinfectionbeforeor afterthesystem.
Systems must be installed andoperated in accordance with manufacturer's
recommended procedures andguidelines.
Warranty: SeeWarranty Cardfor Details.
[]CAUTION
TOreducethe riskof propertydamagedueto water leakage:
Readandfollow Useinstructions beforeinstallationanduse ofthis system.
, Installon COLDwater linesonly,
Complywith al!stateandlocal plumbingcodes.
Install a pressurelimiting device andwater hammerarrester for inletwater pressures
exceeding80 psi (552 kPa).Referto UniformPlumbingCode, Sections608.2 and609.10.
° Neverinstall or operatewhere inletwater pressuremayexceed120 psi (827 kPa).
Protectfilter from freezing.Removefilter intemperaturesbelow 33°F (0,6°C).
o Replacecartridge atspecified serviceinterval.Cartridge MUSTbereplacedatleastevery
12 months.
Topurchaseareplacementfilter,visit yourlocalSearsstoreor call1-800-4-MYHOME®.
Visitus onthewebatwww.sears.com
Distributedby:
SearsBrandManagementCorporation
3333BeverlyRoad
HoffmanEstates,IL60179
19