PelPro PP70 Pellet Stove with 70 lb. Hopper 2,000 sq. ft.

User Manual - Page 12

For PP70.

PDF File Manual, 44 pages, Read Online | Download pdf file

PP70 photo
Loading ...
Loading ...
Loading ...
PelPro Pellet Stove • 7103-171E • January 9, 2020
pelprostoves.com
12
Installing Your Stove
Installing Your Stove
45° elbow is equivalent to 1 foot of straight pipe
90° elbow is equivalent to 3 feet of straight pipe
Notice:
These are guidelines for successful venting
of your pellet Stove. The more vertical rise
you can obtain in your system, the better it will
perform. Horizontal vent runs can accumulate
ash and will need to be cleaned more often.
Try to keep them as short as possible.
Venting Your Stove
The maximum horizontal venting allowed with no vertical venting
attached is 48 inches including one 90° elbow or two 45° elbows.
Addition of any horizontal venting beyond 48 inches requires a
minimum 60 inches of additional vertical vent. Horizontal sections
of vent pipe should have a 1/4 inch rise per foot. We recommend
using the shortest venting and fewest elbows possible when venting
horizontal.
We recommend the use of 4 inch vent with any installation requiring
more than two 90° elbows, or more than 15 feet of venting.
WARNING!
Fire Risk.
Only LISTED venting
components may be
used
NO OTHER vent components may be used.
Substitute or damaged vent components
may impair safe operation.
Minimum Vertical Vent for One Elbow
0
5
10
15
20
0510 15 20
Horizontal Run, (ft)
Course horizontale (PI)
Conduit d’évacuation vertical
minimum pour un coude
Élévation verticale
minimum (pi)
Minimum Vertical Vent for Two Elbows
0
5
10
15
20
0510 15
Length of Horizontal Sections, (ft)
Conduit d’évacuation vertical
minimum pour deux coudes
Longueur des sections horizontales (PI)
7104
8114
9124
Élévation verticale
minimum, (pi)
Minimum Vertical Vent for Three Elbows
0
5
10
15
20
25
024681
01
2
Length of Horizontal Sections (ft)
Conduit d’évacuation vertical
minimum pour trois coudes
Longueur des sections horizontales (PI)
2114
3124
4134
5144
6154
7164
8174
9184
Élévation verticale
minimum (pi)
One 90° Elbow
Total
Horizontal
Minimum
Vertical
Vent
Diameter
4 0 3
5 5 3
6 6 3
7 7 3
8 8 4
9 9 4
10 10 4
11 11 4
12 12 4
13 13 4
14 14 4
15 15 4
16 16 4
17 17 4
18 18 4
19 19 4
Two 90° Elbows
Total
Horizontal
Minimum
Vertical
Vent
Diameter
2 5 3
3 6 3
4 7 3
5 8 3
6 9 3
7 10 4
8 11 4
9 12 4
10 13 4
11 14 4
12 15 4
13 16 4
14 17 4
15 18 4
Three 90° Elbows
Total
Horizontal
Minimum
Vertical
Vent
Diameter
2 11 4
3 12 4
4 13 4
5 14 4
6 15 4
7 16 4
8 17 4
9 18 4
10 19 4
11 20 4
Loading ...
Loading ...
Loading ...