VGC/CVGC Orifice Locations
B
B
C
D
A
*Burner rates will be lowered by 4% per 1000 ft. above altitudes of 2000 ft.
When the conversion is completed, complete the enclosed conversion label and place it next to the rating label.
The rating label for your cooktop is located on the exterior bottom panel of the burner box in the right rear corner.
PROPER LIGHTING AND SHUTDOWN INSTRUCTIONS
1. To ignite the surface burners, turn the knob counter clockwise to any position.
2. Upon ignition of the surface burner, turn the knob to the desired position, (HI, Med, or Low).
3. To shutdown the burner, turn knob clockwise to the OFF position.
4. In case of failure, shut the gas OFF using the installer supplied manual shut-off valve.
Burner LP
Left Front (A) .046 (1.17mm) PB040199
Left Rear (B) .034 (0.86 mm) 044711-000
Center Rear (C) .037 (0.94 mm) PB040202
Center Front (C) .037 (0.94 mm) PB040202
Right Rear (E) .030 (0.76 mm) 044710-000
Right Front (D) .028 (0.71 mm) PB040275
Burner LP
Left Front (A) .046 (1.17mm) PB040199
Left Rear (B) .037 (0.94 mm) PB040202
Center (B)
.037 (0.94 mm) PB040202
Right Rear (C) .030 (0.76 mm) 044710-000
Right Front (D) .028 (0.71 mm) PB040275
Burner 30”W. Model Burner 36”W. Model
Left Front (A)
16,500 BTU LP
(4.9 kW LP)
Left Front (A)
16,500 BTU LP
(4.9 kW LP)
Left Rear (B)
11,000 BTU LP
(3.3 kW LP)
Left Rear (B)
9,000 BTU LP
(2.7 kW LP)
Center (B)
11,000 BTU LP
(3.3 kW LP)
Center Rear (C)
11,000 BTU LP
(3.3 kW LP)
Center Front (C)
11,000 BTU LP
(3.3 kW LP)
Right Rear (C)
7,000 LP
(2.1 kW LP)
Right Rear (E)
7,000 LP
(2.1 kW LP)
Right Front (D)
6,000 BTU LP
(1.8 kW LP)
Right Front (D)
6,000 BTU LP
(1.8 kW LP)
VGC/CVGC530
VGSU/CVGSU530
VGC/CVGC536
VGSU/CVGSU536
B C E
D
CA