Installation
*INSTALLATION*
41
Calculating the countertop cut-out
The frames of the ProLine elements overlap the countertop at the outside right
and left by 5/16" (8mm) on each side.
Add up the widths of the ProLine elements and subtract 5/8" (16mm) from this
sum.
Example:
115/16" + 11 5/16" + 14 15/16" = 37 5/8" - 5/8" = 37"
(288mm+288mm+380mm = 956mm-16mm = 940mm)
The ProLine elements are 11 5/16", 14 15/16" or 22 11/16" (288mm, 380mm or
576mm) wide depending on the model (see “Installation” – “Installation dimen-
sions”).
Spacer bars
When installing several ProLine elements, a spacer bar must be installed between
the individual appliances. The position for securing the spacer bar will depend on
the width of the ProLine element.