NewAir NAC14KWH03 14,000 BTU Portable Air Conditioner 10,000 BTU DOE, Modern AC Design with Easy Setup Window Venting Kit, Self-Evaporative System, Quiet Operation, Dehumidifying Mode with Remote and Timer

User Manual - Page 32

For NAC14KWH03.

PDF File Manual, 105 pages, Download pdf file

Loading ...
Loading ...
Loading ...
EN
www.newair.com 32
Discharge capacitors in a way that will not create sparking.
When brazing is required, the following procedures should be carried out in
the following order:
- Safely remove the refrigerant following local and national regulations. If
the recovery is not required by national regulations, drain the refrigerant
to the outside. Take care that the drained refrigerant will not cause any
danger. In doubt, one person should guard the outlet. Take special care
that drained refrigerant will not float back into the building.
- Purge the refrigerant circuit with oxygen-free nitrogen.
- Evacuate the refrigerant circuit.
- Purge the refrigerant circuit with nitrogen for 5 min (not required for A2L
refrigerants).
- Evacuate again (not required for A2L refrigerants).
- Remove parts to be replaced by cutting or brazing.
- Purge the braze point with nitrogen during the brazing procedure
required for repair.
- Carry out a leak test before charging with refrigerant.
d) Decommissioning
Refrigerant charge should be removed before decommissioning.
Ensure sufficient ventilation at the equipment location.
Be aware that malfunction of the equipment may be caused by refrigerant
loss and a refrigerant leak is possible.
Discharge capacitors in a way that will not create sparking.
Remove the refrigerant. If the recovery is not required by national
regulations, drain the refrigerant to the outside. Take care that the drained
refrigerant will not cause any danger. In doubt, one person should guard the
outlet. Take special care that drained refrigerant will not float back into the
building.
Evacuate the refrigerant circuit.
Purge the refrigerant circuit with nitrogen for 5 min.
Evacuate again.
Fill with nitrogen up to atmospheric pressure.
Put a label on the equipment that the refrigerant is removed.
e) Disposal
Ensure sufficient ventilation in the workspace.
Remove the refrigerant. If the recovery is not required by national
regulations, drain the refrigerant to the outside. Take care that the drained
refrigerant will not cause any danger. In doubt, one person should guard the
Loading ...
Loading ...
Loading ...