Direct Power Wiring (240 V)
All wiring must be completed prior to
installing the built-in electric firebox.
Use 3-conductor wires with ground
(4 wires total) from the power supply
(breaker panel) to the junction box on
the built-in electric firebox.
FIREPLACE JUNCTION BOX
WHITE - N
BLACK - L1
GROUND - G
WHITE - N
BLACK - L1
GROUND - G
240 V
POWER
SUPPLY
BREAKER
PANEL
RED - L2
RED - L2
BLUE - NH
To install 240 V direct power wiring:
1. Pull out the 5 wires marked L1, L2,
N, NH, and G (black, red, white,
blue, and green).
2. Connect N (white) from the built-in
electric firebox to the N (white) from
the power supply.
3. Terminate NH (blue) with a wire
connector (not included).
4. Connect L2 (red) wire from the
built-in electric firebox to the L2
(red) from the power supply.
Electrical
5. Connect L1 (black) wire from the
built-in electric firebox to the L1
(black) from the power supply.
6. Connect the G (green) ground wire
from the built-in electric firebox to
the ground from the power supply.
7. Insert all the wiring back into the
built-in electric firebox and secure
with a cable clamp.
8. Make sure all connections are tight.