KwiKool KBP1000 Bioair+ UV-C HEPA Air Scrubber & Negative Air Machine

User Manual - Page 11

For KBP1000.

PDF File Manual, 14 pages, Read Online | Download pdf file

KBP1000 photo
Loading ...
Loading ...
Loading ...
the cavity, then push the bulb in to its clip in the same manner you pulled the bulb
out.
Plug in the new bulb - Hold the bulb in place with one hand and push the plug on to
the connector with the other. Keep in mind that the connector is not meant for any
direction. The male connection will not match up with the female portion if the
orientation is incorrect. If they do not match up, rotate the plug 90 degrees and try
again.
Re-install filters and close the filter door - Rotate the screws clockwise to securely close the door.
C. Charcoal filter installation for all KwiKool Bio Air systems- This section covers the set up and
installation of the charcoal filter in the field, users that have ordered the charcoal filter installed from the
factory will not need to complete these steps. Open the filter access door Loosen the 2 slotted fasteners
on the filter panel until the door opens. Remove the ULPA/HEPA filter Pull forward on the top of the
filter until it stops, then pull forward on the bottom of the filter until it stops, use this method alternating top
to bottom until the filter clears the frame. Do not jam the filter by pulling too hard. Once removed, you will
see 4 rails attached to the sides, top and bottom of the compartment, these rails stop the HEPA filter from
going into the compartment. Remove the 2 5/16
th
fasteners that are in each rail and move each rail to the
next set of holes in front of the holes that you just removed the fasteners from.
Once all 4 rails have been moved back, re-install the HEPA filter. You will notice the HEPA filter recedes
back an extra 1”.
This allows the charcoal filter to be inserted flush into the frame. Install the charcoal filter by lining the
filter up with the space in front of the HEPA filter and push it into place, close the access door and
operate your KwiKool Bio Airsystem as normal.
VIII / Utilizing your KwiKool System
KwiKool Bio Air utilizes a process that is engineered to meet the high
Demand for cleanliness in a hospital or other critical environments. This
process significantly reduces airborne particulates and microorganisms
as well as drastically reducing the potential for air conditioner related
contaminates.
KwiKool’s Bio Air exclusive “air therapy” process:
Cleans - ULPA filter - a high efficiency ULPA filter which filters 99.999% of
particulates greater than .12 microns in size.
DisinfectsKBA Plus only, Internal UVC light is used to further reduce microorganisms by irradiating the
internal surfaces of the return air chamber.
Retards Growth- Non porous and smooth surface insulation helps
drastically reduce the ability of molds or other microbes from attaching and forming in the return air
compartment.
X / Fault Codes KBA Plus Only
Your KwiKool Bio Air Plus System displays a fault code to indicate that maintenance is needed on your
system; the nature of themaintenance is displayed on the touchscreen panel. See the troubleshooting
guide later in this manual for further information.
UL = 15,000 hours have elapsed (625 Days) with the UV bulbs in operation. (Factory setting, may be
modified by administrators)