TWIN EAGLES VENT HOOD
MODELS: TEVH36-C
TEVH48-C
TEVH60-C
INNOVATION AND INSPIRATION ON FIRE™
FOR RESIDENTIAL USE ONLY.
INSTALLATION INSTRUCTIONS
background
Congratulaons on the purchase of your Twin Eagles Vent Hood! Our products are en-
gineered for precision and designed for style. Each Twin Eagles Vent Hood is manufac-
tured in the USA at our own state of the art facility in California.
This manual will give you easy to follow instrucons for installing, operang and main-
taining your Vent Hood. We recommend reading this manual before your rst use to
ensure safety, proper care and operaon.
At Twin Eagles, we want you to enjoy grilling and spending me together as much as we
do making memories that linger long aer the grill cools down.
Thank you and welcome!
A SPECIAL MESSAGE TO OUR CUSTOMERS...
Dante Cantal
OWNER AND FOUNDER
background
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these instrucons for the Local Electrical Inspectors use.
INSTALLER: Please save these Installaon Instrucons with this unit for owner.
OWNER: PLEASE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the State of California
to cause cancer and reproducve harm. To minimize exposure to the by-products of the burning fuel or from
combuson, always operate this unit according to the use and care manual and provide good venlaon. Cali-
fornia law requires businesses to warn customers of potenal exposure to such substances. For more informa-
on go to www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L’ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne reconnue dans l’Etat
de la Californie pour causer le cancer et des problemes de ferlite. Pour minimiser l’exposion de ces-sous pro-
duits combusbles ou de la combuson, uliser toujours cet appareil en conformitee au manuel d’ulisaon et
d’entreen en s’assurant egalement d’une bonne venlaon. La loi de la Californie exige aux fabricants d’in-
former leurs clients aux risques d’exposion potenelle a de telles substances. Pour plus d’informaon, visiter
le site www.P65Warnings.ca.gov
CUSTOMER CARE
Please record the product informaon below and
refer to it when contacng Twin Eagles.
This informaon is found on the data nameplate,
located on the le hand inside face of the vent hood.
Remove the le most bae to visually access the data
name plate.
SERVICE INFORMATION
Model Number
Serial Number
Date of Purchase
Place of Purchase
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
GETTING STARTED
ELECTRICAL REQUIREMENTS
VENT HOOD KNOCK-OUTS AND MOUNTING
LOCATIONS
TOP EXHAUST
REAR EXHAUST
MOUNTING THE TRANSITION
OUTSIDE PATIO OR LANAI INSTALLATION
BAFFLE FILTER INSTALLATION, USE, AND CARE
TEVH-C EXPLODED VIEW
TEVH-C REPLACEMENT PARTS LIST
TEVH-C WIRING DIAGRAM
WARRANTY
HOW TO OBTAIN SERVICE
1
2
3
4-5
6
7-8
8
9
10-11
12
13
14
15
17
background
1 | www.twineaglesgrills.com
IMPORTANT SAFETY INSTRUCTIONS:
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unaended at high sengs. Boilovers cause smoking and greasy spillovers that
may ignite. Heat oils slowly on low or medium sengs.
B. Always turn hood ON when cooking at high heat or when ambeing food (i.e. Crepes Suzee, Cherries
Jubilee, Peppercorn Beef Flambe’)
C. Clean venlang fans frequently. Grease should not be allowed to accumulate on fan or lter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OB-
SERVE THE FOLLOWING:
A. SMOTHER FLAMES with a close ng lid, cookie sheet, or metal tray, then turn o the burner. BE CARE-
FUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DE-
PARTMENT.
B. NEVER PICK UP A FLAMING PAN - You may be burned.
C. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
D. Use an exnguisher ONLY if:
1. You know you have a Class ABC exnguisher, and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
Read this manual carefully and completely before using your Vent Hood to ensure proper operaon, proper
installaon, proper servicing and to reduce the risk of re, burn hazard and/ or other injury.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. The installaon of this appliance must conform with local codes.
B. Sucient air is needed for proper venlaon of ue gases. Use metal ducng only; no smaller than 10”
diameter. Venlaon must be to the outdoors.
C. When cung or drilling into wall of ceiling, do not damage electrical wiring and other hidden ulies.
D. Before servicing or cleaning unit, unplug from GFCI outlet.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
background
Twin eagles Service (562) 263-3600 | 2
Read this instrucon completely before starng installaon. Planning the complete installaon before start-
ing work is highly recommended. This includes all aspects of the installaon including hood locaon, ducng,
electrical requirements, and adequacy of mounng surfaces.
GETTING STARTED:
1. Remove all packaging materials, labels and protecve plasc lm. DO NOT LEAVE UNIT IN THE SUN WITH
PROTECTIVE PLASTIC FILM ON FOR AN EXTENDED PERIOD OF TIME AS IT WILL BECOME DIFFICULT TO RE-
MOVE.
2. Check to ensure all Vent Hood accessories listed below are included.
3. Assemble parts as per assembly instrucons.
4. Fill out Warranty Registraon Card and mail it to the indicated address, or register online. See page 17.
Vent Hood Accessories TEVH36-C TEVH48-C TEVH60-C
BAFFLE FILTER 3 4 5
CAUTION:
To reduce the risk of re and electric shock, install this vent hood only with Integral Blower TEVI-120I.
The hood is of sucient weight that two installers are recommended to prevent injury or damage to the
hood in handling.
Hood is recommended for use over domesc gas or electric appliances. Not recommended for use over
solid fuel red appliances.
The vent hood is operated by a 3-speed rotary control switch located in the front le of the hood. Me-
dium to low speed will handle most exhaust requirements. Use the high-speed posion for heavy cooktop use
condions. Turn the vent hood on just before cooking to prevent the escape of discharges from the cooking
surface.
The light rotary switch is located to the right of the venlaon control.
OPERATING INSTRUCTIONS:
CLEANING AND MAINTENANCE:
CAUTION: Shut o power to unit at service entrance if you are cleaning the blower.
Use a damp cloth to wipe the outer surface of the blower. Do no use a dripping wet cloth to wipe blower. Nev-
er put your hand int the blower housing.
To clean the hood surface use only mild soap or detergent soluons. Wipe to dry surfaces using a so cloth. If
a stainless surface is being cleaned, always wipe in the direcon of the brush surface. Cleaning aids such as
“Stainless Steel Magic” are available. Never us abrasive cleaners, pads or cloth.
background
3 | www.twineaglesgrills.com
ELECTRICAL REQUIREMENTS:
WARNING
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of elec-
tric shock by providing an escape wire for the electrical current. This appliance is equipped with a cord having
a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and
grounded.
WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualied electrician if the grounding instrucons are not completely understood, or if doubt exists as
to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualied electrician install an outlet
near the appliance.
NOTE:
Venlator requires a dedicated 15 AMP
Power Supply.
The appliance should only be taken apart by a qualied technician, or electrical shock may occur. It is
rated at 120V, 5.4 Amps, 60Hz.
REMINDER:
Keep any electrical supply cord away from any heated features.
Unit comes with three-pronged power cord pre-installed. Vent hood must be plugged into a GFCI protected
branch circuit. Suitable for use in damp locaons when installed in a GFCI protected branch circuit.
HALOGEN LAMP WATTAGE: 40 WATTS PER LAMP
background
Twin eagles Service (562) 263-3600 | 4
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS:
FIG 1A
1
2
FOR REAR EXHAUST
FOR TOP EXHAUST
UNIT MUST BE VENTED TO THE OUTSIDE OF THE BUILDING.
! !
NOTE: The hood is of sucient weight that two installers are recommended to prevent injury or damage to the
hood in handling.
Before starng the installaon, you must idenfy if the installaon will be a rear exhaust or top exhaust instal-
laon.
Begin the installaon by removing the appropriate knock-out that will provide the top or rear exhaust point.
See FIG 1A for knock-out locaons.
CAUTION:
When knock outs are removed the edges
will be sharp!!! Sharp edges should be led
or covered with metal tape.
! !
background
5 | www.twineaglesgrills.com
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS -cont:
FIG 1B
MOUNTING HOLEMOUNTING HOLE
MOUNTING HOLEMOUNTING HOLE
X 4
MOUNTING SCREW
Installaon of the Vent Hood should also take into account the unit that the Vent Hood is to be installed above.
For best venlaon of smoke and heat, make sure the vent hoof is centered above the appliance and a min-
imum of 36 inches above the cooking surface. Refer back to the appliance manual to be sure distances and
clearances to combusble construcon are maintained.
Mounng locaons are shown in FIG 1B:
Mounng surface must be a minimum of 3/4” thick. Mount Vent Hood to desired construcon using #10
wood screws. A minimum of four #10 wood screws are needed to mount the Vent Hood. Longer screws may
be required if wall board or other nonstructural surfaces are used between the hood and the main mounng
surface. Anchors may be required if mounng screws do not engage the wood structure.
Use of furring strips to level the cabinet mounng surface may be required. Refer to FIG 2 for ducng clearanc-
es and furring strip locaons.
background
Twin eagles Service (562) 263-3600 | 6
TOP EXHAUST
FIG 2
BOTTOM VIEW OF CABINET
WIRING ACCESS BACK WALL
ADD FURRING STRIPS TO PROVIDE AN EVEN BOT-
TOM SURFACE FOR THE HOOD MOUNTING.
FIG 3
REMOVE KNOCK OUT # 2
ROTATE
INTO
POSITION
& SECURE
WITH 2
SCREWS
B A
10” DISCHARGE WITH TRANSITION WILL BE ON THE
CENTER LINE OF HOOD WIDTH AND ON CENTER LIE
OF 12” DIMENSION.
FIG 4
VERTICAL DISCHARGE
3”
ALL HOODS
30”
18”
12”
10” DUCT TO
DISCHARGE W/
ROOF OF WALL
CAP
TRANSITION
HOOD
WIDTH
DIM A
36” 8 3/8”
48” 17 1/2”
60” 23 7/16”
background
7 | www.twineaglesgrills.com
REAR EXHAUST
ROTATE
INTO
POSITION
& SECURE
WITH 2
SCREWS
FIG 6
A
B
FIG 5
BOTTOM VIEW OF CABINET
ADD FURRING STRIPS TO PROVIDE AN EVEN BOT-
TOM SURFACE FOR THE HOOD MOUNTING.
WIRING ACCESS
BACK WALL
FIG 7
SECURE TRANSITION TO HOOD
USING #10 SHEET METAL SCREWS.
TAPE ALL JOINTS AND SEAMS.
ROUTE TO OUTSIDE
WITH WALL CAP
TRANSITION TO 10”
DUCT OR WALL CAP
HOOD
WIDTH
DIM A
36” 8 3/8”
48” 17 1/2”
60” 23 7/16”
background
Twin eagles Service (562) 263-3600 | 8
FIG 8
REAR EXHAUST
CUT HOLE IN DRYWALL TO ACCEPT
TRANSITION
= CENTER OF ROUND DUCT USING
TWIN EAGLES TRANSITION
A
A
MOUNTING THE TRANSITION:
X 4
FIG 9
TOP EXHAUST
FIG 10
REAR EXHAUST
#10-24 METAL CUTTING SCREWS
X 4
#10-24 METAL CUTTING SCREWS
background
9 | www.twineaglesgrills.com
OUTSIDE PATIO or LANAI
INSTALLATION
Construcon methods and installaon shall comply with all local building codes. Internal ducng shall be
sealed using outdoor rated metal tape.
The Twin Eagles hood with stainless steel canopy is approved for installaon in an outside pao or lanai area
if the area is covered with a protecve roof over the hood (wall style hoods are to be also mounted to a solid
protecve rear wall) and installed with a GFCI protected branch circuit. Roof or Wall Caps are to be sealed to
prevent moisture migraon to structure interior; use an outdoor rated sealant suitable for adhesion to the
installaon materials. See FIG 6 for rear exhaust installaon and FIG 3 for top exhaust installaon.
A
A
B
A = 42” MINIMUM
FRONT VIEW
B = 30” MINIMUM
SIDE VIEW
REAR
EXHAUST
*
* = TOTAL OVERALL
WIDTH WITH HOOD
FIG 9
WALL
CAP
The roof shall cover the top of the hood and extend a minimum of 42” from each side of the hood and 30”
minimum from the outer edges of the hood front.
Since, outdoor areas are subject to strong cross dras it is recommended that the hood extend at least 3
inches and preferably 6 inches, over either side of the cooking area to maximize the cooking discharge capture
area. Cross dras will aect the eciency of the venlaon system and cooking discharge can escape capture
by the hood/venlaon system. Be sure to plan for adequate venlator (blower) capacity to minimize cross
dras inuencing the removal of cooking discharges.
The installaon instrucons that accompanies the hood shall be followed to ensure all safety instrucons and
guidelines are adhered to.
Suitable for use in damp locaons when
installed in a GFCI protected branch circuit.
See FIG 10 for structure with elevated roof / ceiling
background
Twin eagles Service (562) 263-3600 | 10
AA
B
A = 42” MINIMUM
FRONT VIEW
B = 30” MINIMUM
SIDE VIEW
TOP
EXHAUST
*
* = TOTAL OVERALL
WIDTH WITH HOOD
FIG 10
ROOF
CAP
12”
background
11 | www.twineaglesgrills.com
BAFFLE FILTER
INSTALLATION, USE AND CARE
INSTALLER: Please leave these installaon instrucons with unit for the owner.
1. Remove all packaging and the producve plasc covering from lters.
2. Grasp the lter by the center bae, see FIG 11, with the spring end facing you and the grease collector
channel is facing down and toward the rear of the hood. Posion the spring end of the lter into the up-
per channel of the front escutcheon, compress the spring by pulling the lter toward you and rotate the
rear of the lter up and into the rear retaining recess formed by the rear escutcheon and retaining clip.
Release the lter, being sure it is posioned properly in the channels. You should be able to push and pull
down on the lter without having it come out of posion. You can bend the spring lightly outward if the
lter is no pressing securely against the rear escutcheon.
3. The lter has an integral grease collector and is dishwasher safe. To clean your lter simply grasp the l-
ter by its center bae, pull toward the front of the hood and rotate the rear of the lter down and away
from the hood, see FIG 12.
4. For best dishwasher results, posion the lters in the dishwasher rack with the baes posioned hori-
zontally.
BACKDRAFT DAMPER: It is recommended that a backdra damper in all installaons. In cold weather installa-
ons it is necessary to use a backdra damper to minimize backow of cold air into the room. A non-metallic
thermal break should also be used to minimize conducon of outside temperatures through the ductwork.
The thermal break should be located as close as possible to where the ducng enter the heater poron of the
room.
FIG 11
1
2
3
WRONG
GREASE
COLLECTOR
CHANNEL
1. POSITION IN UPPER CHANNEL
2. PULL
3. ROTATE UP AND INTO RETAINING RECESS
FIG 12
1
2
3
1. PULL
2. ROTATE DOWN
3. REMOVE FILTER
background
Twin eagles Service (562) 263-3600 | 12
TEVH-C
EXPLODED VIEW
* - #12 AND #13 SOLD SEPARATELY
background
13 | www.twineaglesgrills.com
TEVH-C
REPLACEMENT PARTS LIST
ITEM
NO.
PART
NUMBER
DESCRIPTION TEVH36-C TEVH48-C TEVH60-C
1 S21160-36Y 36” VENT HOOD ASSEMBLY 1 - -
2 S21160-48Y 48” VENT HOOD ASSEMBLY - 1 -
3 S21160-60Y 60” VENT HOOD ASSEMBLY - - 1
4 S21166-36Y 36” CONTROL PANEL ASSEMBLY 1 - -
5 S21166-48Y 48” CONTROL PANEL ASSEMBLY - 1 -
6 S21166-60Y 60” CONTROL PANEL ASSEMBLY - - 1
7 S21167 RECEPTACLE BOX COVER 1 1 1
8 S21171 ELECTRICAL BOX BODY 1 1 1
9 S21172 ELECTRICAL BOX COVER 1 1 1
10 S21173 SWITCH PANEL 1 1 1
11 S21164Y BAFFLE FILTER ASSEMBLY 3 4 5
12* S16477 BLOWER MOTOR ASSEMBLY (SOLD SEPARATELY) 1 1 1
13* S13166 VENT HOOD DAMPER (SOLD SEPARATELY) 1 1 1
14 S13203 TWIN EAGLES EMBLEM 1 1 1
15 S16494 HALOGEN LIGHT 2 2 2
16 S13501 HIGH TEMP CONTROL KNOB 2 2 2
17 S16493 3-POS ROTARY SWITCH 1 1 1
18 S16492 4-POS ROTARY SWITCH 1 1 1
19 S14536-24 HEAVY DUTY FLEXIBLE CONDUIT 1 1 1
20 S14537 HEAVY DUTY CONNECTOR 2 2 2
21 S16112 STRAIN RELIEF 1 1 1
22 S16111Y ELECTRICAL CORD ASSEMBLY 1 1 1
PARTS NOT SHOWN
23 S16482 WIRE HARNESS, VENT HOOD ADAPTER 1 1 1
24 S16496 WIRE HARNESS, LIGHT SWITCH TO BLOWER MOTOR 1 1 1
25 S16497 WIRE HARNESS, RECEPTACLE PLUG 1 1 1
26 S16498 WIRE HARNESS, BM ROTARY HI TO RECEPTACLE PLUG 1 1 1
27 S16499 WIRE HARNESS, BM ROTARY LOW TO RECEPTACLE PLUG 1 1 1
28 S16501 WIRE HARNESS, BM ROTARY MID TO RECEPTACLE PLUG 1 1 1
29 S16502-36 WIRE HARNESS, SWITCH TO LH AND RH LIGHT, 36 1 - -
30 S16502-48 WIRE HARNESS, SWITCH TO LH AND RH LIGHT, 48 - 1 -
31 S16502-60 WIRE HARNESS, SWITCH TO LH AND RH LIGHT, 60 - - 1
32 S16503-36 WIRE HARNESS, SWITCH WITH BRIDGE TO LH LIGHT, 36 1 - -
33 S16503-48 WIRE HARNESS, SWITCH WITH BRIDGE TO LH LIGHT, 48 - 1 -
34 S16503-60 WIRE HARNESS, SWITCH WITH BRIDGE TO LH LIGHT, 60 - - 1
35 S16504-36 WIRE HARNESS, SWITCH WITH BRIDGE TO RH LIGHT, 36 1 - -
36 S16504-48 WIRE HARNESS, SWITCH WITH BRIDGE TO RH LIGHT, 48 - 1 -
37 S16504-60 WIRE HARNESS, SWITCH WITH BRIDGE TO RH LIGHT, 60 - - 1
background
Twin eagles Service (562) 263-3600 | 14
TEVH-C
WIRING DIAGRAM
W 1 8 GA
BLK 18 GA
BLU 18 GA
R 18 GA
HHOOOODD
RREECCEEPPTTAACCLLEE
BBOOXX
PPOOWWEERR SSUUPPPPLLYY
LL11
BLK 18 GA
GGNN
GR N 1 8 GA
WHT 18 GA
11
AA
22
33
BB
44
RROOTTAARRYY
LLIIGGHHTT
SSWWIITTCCHH
LLEEFFTT
LLIIGGHHTT
RRIIGGHHTT
LLIIGGHHTT
11
LLOO
MMEEDD
HHII
66
44
22
33--SSPPDD
RROOTTAARRYY
SSWWIITTCCHH
BBLLOOWWEERR
MMOOTTOORR
WHT 18 GA
BLK 12 GA
BLK 18 GA
BLU 18 GA
R 18 GA
BLK 18 GA
WHT 18 GA
BLK 18 GA
BLK 18 GA
WHT 18 GA
WHT 18 GA
WHT 18 GA
WHT 18 GA
WHT 18 GA
WHT 18 GA
background
15 | www.twineaglesgrills.com
TEVH-C
WARRANTY
LIMITED TWO YEAR WARRANTY: Twin Eagles warrants the Vent Hood to be free from defects in materials and workman-
ship under normal residenal use for a period of two years from the original date of purchase. The actual part will be
repaired or replaced, free of charge, with the owner paying for all other costs including labor, shipping and handling.
ONE-YEAR FULL WARRANTY: Twin Eagles warrants the Vent Hood and all other components to be free from defects in
materials and workmanship under normal residenal use for a period of one year from the original date of purchase.
Twin Eagles will repair or replace parts found to be defecve at no cost to the original purchaser. Warranty service must
be performed by a Twin Eagles authorized representave during normal business hours.
NINETY (90) DAY RESIDENTIAL PLUS WARRANTY: This warranty applies to applicaons where use of the product ex-
tends beyond normal residenal use such as bed and breakfast inn and private clubs. The actual part will be repaired or
replaced, free of charge, with the owner paying for all other costs including labor, shipping and handling. This warranty
excludes all commercial locaons such as restaurants and food service locaons.
WARRANTY LIMITATIONS & EXCLUSIONS
This warranty shall apply only to the products purchased and located in the connental United States and Canada. The
warranty coverage begins on the original date of purchase and proof of date of purchase is required. To acvate the
warranty, we require that you send in the aached warranty registraon card. This warranty applies only to the original
owner and may not be transferred.
This warranty excludes discoloraon, surface scratches, weather and atmospheric related staining, and minor surface
rust and oxidaon which are normal condions and are to be expected with any outdoor product. This warranty does not
apply to damages resulng from negligence, alteraon, misuse, abuse, accident, natural disaster, loss of electrical power
to the product for any reason, improper installaon or improper operaon, unauthorized adjustments or calibraons,
dings, dents, scratches, or damages due to harsh cleaning chemicals. This warranty does not apply to commercial use,
or to products with altered or removed serial numbers. Display models are generally sold “as is” and are subject to the
following warranty exclusions: missing components, scratches, dents and other exterior or cosmec damages, electri-
cal, gas and ignion system. Twin Eagles shall not be liable for incidental, consequenal, special or conngent damages
resulng from its breach of this wrien warranty or any implied warranty.
WARRANTY SERVICE & REPLACEMENT PARTS: Call your authorized selling dealer or call Twin Eagles directly at (562) 263-
3600. Be prepared to furnish the following informaon: Purchasers name, model and serial number of the Vent Hood,
date of purchase and the accurate descripon of the problem. Twin Eagles will not pay for service calls for correcng an
installaon problem. Owner shall be responsible for proper installaon, providing normal care and maintenance, pro-
viding proof of purchase upon request and making the side burner accessible for service. In the event of any warranty
replacement, all removal, replacement, installaon and shipping costs are the responsibility of the owner.
Some states do not allow limitaons on how long an implied warranty lasts, or the exclusions of or limitaons on conse-
quenal damages. This warranty gives you specic legal rights and you may have other rights, which vary from state to
state.
background
Twin eagles Service (562) 263-3600 | 16
For service, please contact your Twin Eagles dealer or call Twin Eagles direct at (562) 263-3600 or fax
(562) 802-3391
Mailing address:
Twin Eagles, Inc.
13259 East 166th Street
Cerritos, CA 90703
Visit us at www.twineaglesgrills.com
Please provide:
Model number
Serial Number (located on the inner le hand face of the vent hood. Remove le most Filter Bae to
access Data Plate)
Date of Purchase
A descripon of the problem
WARRANTY REGISTRATION
This warranty registraon card must be returned within thirty days of purchase to properly acvate your
warranty. This informaon is for our internal use only.
Or you may register online at hps://twineaglesgrills.com/about-us/contact-us/
Customer Name: Model #:
Address: Serial #:
City, State: Date Purchased:
Zip: Dealers Name:
Phone #: Dealers Address:
E-mail:
INNOVATION AND INSPIRATION ON FIRE™
SERVICE
HOW TO OBTAIN
background
Place
Postage
Here
CUT HERE
INNOVATION AND INSPIRATION ON FIRE™
Customer Service
ATTN: Warranty Department
13259 East 166th Street
Cerritos, CA 90703
Fax no. (562) 802-3391
P/N: 24379B 05/21

Specifications

Indexed Terms: Dryer, Heat Pump

Miele TEVH60C Questions and Answers

Questions and Answers

Related Products

Product Miele PT7135WH image
Miele PT7135WH Dryer
2022-05-29 5 docs
Product Miele TCR780WP image
Miele TCR780WP Dryer
2022-05-11 7 docs
Product Miele TXI680WP image
Miele TXI680WP Dryer
2021-10-09 2 docs
Product Miele PDR908 image
Miele PDR908 Dryer
2021-07-10 2 docs