21
Installation Instructions
ELECTRICAL CONNECTIONS
Use only a 3-conductor or a 4-conductor UL-listed
range cord. These cords may be provided with ring ter-
minals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum
volt range is required. A 50 amp range cord is not rec-
ommended but if used, it should be marked for use
with nominal 13/8" diameter connection openings.
Care should be taken to center the cable and strain re-
lief within the knockout hole to keep the edge from
damaging the cable.
Because range terminals are not accessible after
range is in position, flexible service conduit or cord
must be used.
NOTE: If conduit is being used, go to Step 3D and then
to Step 6 or 7.
On some models, a filter capacitor may be con-
nected between the black and white leads on the
junction block.
ALL NEW BRANCH CIRCUIT INSTAL-
LATIONS, MOBILE HOMES, RECRE-
ATIONAL VEHICLES AND INSTALLA-
TIONS WHERE LOCAL CODES DO
NOT ALLOW GROUNDING
THROUGH NEUTRAL, REQUIRE A 4-
CONDUCTOR CORD OR CONDUIT.
POWER CORD AND STRAIN RELIEF
INSTALLATION
3
A
B
Remove the wire cover (on the back of the range) by
removing two (2) screws using a Phillips screw driver.
Do not discard these screws.
Remove the knockout ring (1 1/8" or 1 3/8" depending
on your model) located on bracket directly below
the terminal block. To remove the knockout, use a
pair of pliers to bend the knock-out ring away from
the bracket and twist until ring is removed.