6-5 REFRIGERATING CYCLE
Troubleshooting Chart
STATE OF STATE OF THE TEMPERATURE
CAUSE THE SET EVAPORATOR OF THE REMARKS
COMPRESSOR
PARTIAL Freezer Low flowing sound of A little higher Refrigerant level is low due
LEAKAGE compartment and Refrigerant is heard and than ambient to a leak.
Refrigerator don't frost forms in inlet only temperature. Normal cooling is possible
r- cool normally, when injecting of Refrigerant
m
> the regular amount.
WHOLE Freezer Flowing sound of refrigerant Equal to ambient No discharging of Refrigerant.
LEAKAGE compartment and is not heard and frost isn't temperature. Normal cooling is possible
Refrigerator don't formed, when injecting of Refrigerant
cool normally, the regular amount.
PARTIAL Freeze Flowing sound of refrigerant A little higher Normal discharging of
CLOG compartment and is heard and frost forms than ambient refrigerant.
Refrigerator don't in inlet only. temperature. ° The capillary tube is faulty.
G)
m cool normally.
o
"_ WHOLE Freezer ' F]owmg sound of refrigerant Equal to ambient Normal discharging of
_: CLOG compartment and is not heard and frost isn't temperature. Refrigerant.
-_°_ Refrigeratordcolcool formed.
MOISTURE Cooling operation Flowing sound of refrigerant Lower than Cooling operation restarts
CLOG stops periodically, is not heard and frost melts, ambient when heating the inlet of
temperature capillary tube.
O COMP- Freezer and Low flowing sound of A little higher Low pressure at high side
O _ RESStON Refrigerator refrigerant is heard and ambient of compressor due to low
-o"r
rr don't cool. frost forms in inlet only. temperature, refrigerant level.
m_,
o)-
< NO COMP- No compressing Flowing sound of refrigerant Equal to ambient No pressure of high pressure
O rr RESSION operation, is not heard and no frost, temperature, part in the compressor.
z
Leakage Detection
Observe discharging pointofrefrigerant whichmay be in the oil dischargingpart inthe compressorand holeofevaporator.
Check if frost
Check if compressor YES forms or not in
runs or not.
Evaporator.
Frost formed normally
_ i Normal amount
Moisture Clog ! ! FaoUlmt_oressor. I
Check Compressor
Check ifoil
No frost l, leaks or not. |'
or forms .....
in inlet only J,
[ Observe the discharged
, amount of Refrigerant.
I No or much amount
I Inject refrigerant to compressor
and check cooling operation.
co"b!01;'.... I
. . ]I gg Y .
Frost formed nermally
YES
t
,J Gas.!eakag e"
(Check the leakage peint)
-14-