Installation
60
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/31 - 37 mbar AUX SR RR R UR2 (int + ext) UR3 UR3*
Rated heating capacity (kW)
1.1 1.7 2.6 3.1 1.1 + 3.7 3.9 3.3
Nozzle diameter (1/100 mm)
48 60 73 80 48 + 85 89 82
Reduced flow rate (W)
400 450 650 750 400 + 1400 1600 1600
Primary air (mm)
2224 4 + 10 43
Rated flow rate G30 (g/h)
80 124 189 225 80 + 269 284 240
Rated flow rate G31 (g/h)
79 121 186 221 79 + 264 279 236
9 LPG G30/31 - 50 mbar AUX SR RR R UR2 (int + ext) UR3 UR3*
Rated heating capacity (kW)
1.1 1.7 2.6 3.1 1.1 + 3.7 3.9 3.3
Nozzle diameter (1/100 mm)
42 54 67 73 42 + 80 82 76
Reduced flow rate (W)
400 450 650 750 400 + 1400 1400 1400
Primary air (mm)
1.5 2 1.5 2 3 + 10 2.5 2.5
Rated flow rate G30 (g/h)
80 124 189 225 80 + 269 284 240
Rated flow rate G31 (g/h)
79 121 186 221 79 + 264 279 236
10 Town gas G110 - 8 mbar AUX SR RR R UR2 (int + ext) UR3 UR3*
Rated heating capacity (kW)
1.1 1.7 2.6 3.1 1.1 + 3.7 3.8 3.3
Nozzle diameter (1/100 mm)
132 165 210 240 132 + 290 290 250
Reduced flow rate (W)
400 450 650 750 400 + 1200 1400 1400
Primary air (mm)
1111.5 1 + 3 22