10
DOWN UNDER SERIES II
Battery Protection Mode Settings
The fridge is equipped with a multi-level battery monitor that protects your vehicle battery
against excessive discharging when the fridge is connected to the on-board 12V/24V
supply. If the refrigerator is operated when the vehicles ignition is switched o, the fridge
switches o automatically as soon as the supply voltage falls below a set level. The fridge
will switch back on once the battery has been recharged to the restart voltage level. See
recommendations below:
Battery Protection Mode L M H
Switch-o voltage at 12V 10.1V 10.5V 11.1V
Restart voltage at 12V 10.9V 11.4V 12.4V
Switch-o voltage at 24V 21.5V 22.3V 24.3V
Restart voltage at 24V 22.7V 23.7V 25.7V
When the power to the refrigerator is supplied by the starter battery of a car, select battery
mode “H”. In every other instance, EvaKool recommends using the “L” / low setting. This
is safe for your auxiliary battery and will maximise how long your fridge can run o your
battery on a single charge. Keep in mind, best 12V practice is to keep your battery as
charged as possible to maximise its lifespan. If you wish to operate the fridge from an AC
power supply, set the battery mode to “L.
Helpful Hints
Pre-chill your fridge before use, this can be done the night before you leave for your
trip on 240V to save on battery power. This will allow your fridge to achieve the
desired temperature quicker.
Clean your fridge regularly by following the cleaning and maintenance guide on
page 15. This will avoid ice forming of the cooling plates and ensure the condenser is
free from dust and lint for optimum performance.
Do not store any electrical equipment inside the fridge aer use.
Leave the fridge lid le ajar aer use to prevent mold.
Use the included baskets to ensure air circulates freely around the cabinet.
Ensure the vents are not obstructed to allow maximum airflow.
Refrain from unnecessary opening of the unit.