44 MAINTENANCE
Application Guidelines / Water Supply Parameters
Note that while the testing was performed under
standard laboratory conditions, actual performance
may vary.
Service Flow 0.5 gpm (1.9 Ipm)
Water Supply Communky or private well
-- Potable Water
Water Pressure 20 -120 psi (138 - 827 kPa)
i Water Temperature 33-100°F (0.6 -37.8°C)
Capacity 200 gallons (757 liters)
NSF System Trade Name Code : ADQ73613401-S
NSF Replacement Code : ADQ73613401
It is essential that the manufacturer's
recommended installation, maintenance and filter
replacement requirements be carried out for the
product to perform as advertised.
Replacement Cartridge: ADQ73613401
For estimated costs of replacement elements
please call 1-877-714-7486 or visit our website at
www.lge.com
Refer to the "warranty" section of the
Refrigerator Owner's Manual for Limited Warranty
information.
SAFETY INFORMATION
Read, understand, and follow all safety Information contained in these instructions prior to installation and
use of this product. Retain these instructions for future reference.
F-Z_ WARNING -°,
To reduce the risk associated with the ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate /
disinfection before or after the system. Systems certified for cyst reduction may be used on /
disinfected water that may contain filterable cysts.
F-Z_ CAUTION
Please note that water could fall while replacing filter which could result property damage.
To reduce the risk associated with property damage due to water leakage:
o Read and follow Use Instructions before installation and use of this system.
Installation must comply with existing state or local plumbing codes.
Protect filter from freezing Drain filter when room temperature drops below 33°F (0.6°C).
Do net install if water pressure exceeds 120 psi (827 kPa). If your water pressure exceeds 80 psi,
you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how
to check your water pressure.
Do not install where water hammer conditions may occur, tf water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to
check for this condition.
Do not install on hot water supply lines. Install on cold water lines only. The maximum operating
water temperature of this filter system is 100°F (37.8°C).
Where a backflow prevention device is installed on a water system, a device for controlling pressur_
due to thermal expansion must be installed.
The disposable filter cartridge must be replaced every six months, at the rated capacity or if a
noticeable reduction in flow rate occurs.
NSF is a trademark of NSFInternational. LGis a trademark of LGCorp. MCM Co..Ltd.