Fig.2.11
G
Fig. 2.12
SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:
Rapid and triple ring burners
- Light the burner
- Set the gas valve to LO position
- Remove the knob
- With a thin screwdriver pass by the hole of microswitch and turn the screw F until
adjustment is correct (fig. 2.11).
Inside crown of DUAL burner
- Light the DUAL burner
- Set the gas valve to '_ position
- Remove the knob
- Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.12).
Outside crowns of DUAL burner
- Light the DUAL burner
Set the gas valve to
position
- Remove the knob
- Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.12).
For LP/PROPANE gas, tighten the adjustment screws completely.
After regulation repeat the operations indicated in paragraph "2. Pressure regulator" at
page 13.
If the range has been disconnected and then connected again to the gas supply line
repeat the operations indicated in paragraph "5. Leak Testing" at page 16.
IM PORTANT:
After conversion to LP/PROPANE gas has been carried out affix on the back of the
appliance, near the data plate, the conversion label supplied and also affix a conversion
label at page 3 of this instruction manual.