Connect a 3/8” diameter pipe to the tap water line.
The pressure of the tap water line should be maintained at a level between 20psi (1.4bar) and
80psi (5.5bar). The tap water line and drain pipeline should be planned and prepared at the
place of installation. The electric power, tap water pipeline, and drain pipeline should satisfy all
the provisions under local laws and regulations.
NOTE: The ice maker is designed for use in a fixed position, but it may be necessary to pull the
appliance forward for service. Therefore, do not install any material at the front, upper, and
lower end of the appliance, which may act as an obstacle when moving the ice maker.
Installing the Purification Filter
This ice maker requires a purification filter (included) in order to operate. The filter cycle is typically 6
months, but might be shorter depending on your environment and the quality of your water.
Replacement filters can be ordered online at summitappliance.com/filter100.
To install the filter upon setup:
1. Remove the round punch-out on the lower right hand side of your ice maker’s front. It has been
precut to make this process easy. You can discard the plastic cutout, as you will no longer need
it.
2. Insert the filter into the hole, turning it clockwise until it is locked in place.
3. Upon first starting the ice maker, check the area around the filter to ensure there are no leaks. If
you see any water, reinsert the filter and make sure it is properly connected.
OPERATION
Once the power supply, water intake supply, water drain pipe, and purification filter have been
properly installed, the ice maker is ready for use.
1. Open the water intake valve.
2. Turn the power switch on the front panel to the “ICE” position. The first round of ice should be
ready approximately 20-30 minutes after the operation starts.
NOTE: Before using any ice, make two full batches of ice and discard to ensure future batches are
clean and sanitary.
Ice Full Sensor
An automatic sensor stops ice making once the ice box is full. Remove the finished ice from the ice
basin to resume the automatic ice making operation.
Ice Thickness Sensor
An ice bridge thickness of 3.2mm (.012) is set as the factory default. Rotate
the control screw counter-clockwise to make the ice bridge thinner, and
clockwise to make the ice bridge thicker.