Loading ...
Loading ...
Loading ...
Rinnai Tankless Water Heater Installation and Operation Manual 59



or greater.
Information in table
obtained from NFPA 54,
ANSI Z223.1 - 2015.

1/2 3/4 1 1 1/4
 
10 (3) 454 949  
20 (6) 312 652  
30 (9) 250 524 986 
40 (12) 214 448 844 
50 (15) 190 397 748 
60 (18) 172 360 678 
70 (21) 158 331 624 
80 (24) 147 308 580 
90 (27) 138 289 544 
100 (30) 131 273 514 
Natural Gas

Rinnai Model Gas Input:
Additional Appliance Total Gas Input:

Cubic Feet Per Hour (CFH):
Answer:



A
199,000
Btu/hr
B
65,000
Btu/hr
C
1,000

3
(CFH)
A + B
C
(CFH)
199,000+65,000
1,000
(CFH)
264

3
/hr
Schedule 40 Metallic Pipe
Inlet Pressure: Less than 2 psi
 0.60
Propane (Undiluted)

Information in table obtained from
NFPA 54, ANSI Z223.1 - 2015.

1/2 3/4 1 1 1/4
 
10 (3) 291 608  
20 (6) 200 418 787 
30 (9) 160 336 632 
40 (12) 137 287 541 
50 (15) 122 255 480 985
60 (18) 110 231 434 892
80 (24) 101 212 400 821
100 (30) 94 197 372 763
Schedule 40 Metallic Pipe
Inlet Pressure: 
 1.50

Rinnai Model Gas Input:
Additional Appliance Total Gas Input:
Total Gas Input:
Answer:



A
199,000
Btu/hr
B
65,000
Btu/hr
Total Gas
Input
264,000
Btu/hr
Total Gas
Input
=
A + B
Total Gas
Input
=
199,000 + 65,000
Loading ...
Loading ...