Revision 1
3
Function
Connect the lead to the power outlet, attach the outlet hose if available. Start the machine by pressing
the start knob. The air cleaner has two speeds.
The air cleaner separates material in two stages:
The first stage uses a coarse filter. This traps the bigger particles and acts as protection for the main
filter. The coarse filter should be changed on a daily basis.
The second absolute filter separates the unhealthy dust that is invisible to the eye.
Coarse filter characteristics
The coarse filter is strong and easy to change. It has low pressure drop and good separation capability.
The coarse filter takes care of big particles and acts as protection for the absolute filter.
Main filter characteristics
The main filter is an absolute filter with class HEPA H13 that is dimensioned for fine, dry dust and
should be preceded by a pre-filter.
Caution
The operating life of the absolute filter decreases and can be completely destroyed if exposed
to water.
Caution
The absolute filters cannot be cleaned and must be replaced when full.
Filter indicator
A600/A1200 has two filter indicators connected to a warning light which measures the pressure drop
over the filter. If the pressure drop is too high, a orange lamp light up, indicating that the absolute
filter should be changed. Using the air cleaner when light is showing will reduce the effectiveness of
the machine. When the pressuredrop is too low, a red lamp will light up, indicating that the Hepa filter
is leaking/damaged and needs to be replaced immediately.
Fan
The air cleaner is equipped with a single, 1 phase fan.
Risk of dust dispersion - Use of personal safety equipment
Unhealthy dust can be spread when cleaning the coarse filter and during filter change.
Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask
conforming to protection class FFP2.