Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"
(12.7 cm). Cut 11/2" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape
ends of wires into a hook shape.
<,
3. Connect ground wire (green or bare) of direct wire cable to external ground conductor
screw. Tighten screw.
(12, 7
When connecting to the terminal block, place the hooked end of the wire under the screw of
the terminal block (hook facing right), squeeze hooked end together and tighten screw, as
shown.
I,
2.
Remove center silver-colored terminal block screw.
Remove neutral ground wire from external ground conductor screw. Connect neutral
ground wire and place the hooked end (hook facing right) of the neutral wire (white or
center wire) cff direct wire cable under the cente'r _crew cff the terminal blc_ck £queeTe
hooked ends together. Tighten screw.
/
A. £xternal ground conductor screw
B. Ground wir_" (green or bar_') of power supply cable
C. _" ( 1.9 cm) UL listed strain relie'f
D. C_'nter silver-color_'d tern'linal block scr_'w
E. Neutral ground wir_"
[. Neutral wire twhite or cente'r wh_')
Place the hooked ends of the other direct wire cable wires under the outer terminal block
screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!! !!
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
(JOWl] screw.
7. You have completed your electrical connection. Now go to "Venting Requirements."
A. Fxternal ground conductor screw - Dotted line shows
position of NEUTRAL ground wir_' before' being moved to
center silve'r-co/ore'd terminal block scr_'w.
B. C_'nter silver-colored terminal block scre'w
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. !4" ( 1.9 cm) UL listed strain relic4