Installation Manual
6. OUTDOOR UNIT INSTALLATION
Outdoor Unit Installation Instructions
Step 1: Select installation location
The outdoor unit should be installed in the location that
meets the following requirements:
Place the outdoor unit as close to the indoor unit as
possible.
Ensure that there is enough room for installation and
maintenance.
The air inlet and outlet must not be obstructed or
exposed to strong wind.
Ensure the location of the unit will not be subject to
snowdrifts, accumulation of leaves or other seasonal
debris. If possible, provide an awning for the unit.
Ensure the awning does not obstruct airflow.
The installation area must be dry and well ventilated.
There must be enough room to install the connecting
pipesandcablesandtoaccessthemformaintenance.
The area must be free of combustible gases and
chemicals.
The pipe length between the outdoor and indoor
unitTmVTU not exceed the maximum allowable pipe
length.
If possible, DO NOT install the unit where it XJMMCF
exposed to direct sunlight.
If possible, make sure the unit is located far away
from neighborJOH propertJFT so the noise fromthe
unit will not disturb PUIFST.
If the location is exposed to strong winds (for
example near a seaside), the unit TIPVME be placed
against B wall to shelter it from the wind. Ifnecessary,
use an awning. (See Fig. 6.1 BOE'JH 6.2)
Install the indoor and outdoor units, cables and wires
at least 1 meter from televisions or radios to prevent
static or image distortion. Depending on the radio
waves, a 1 meter distance may not be enough to
eliminate all interference.
Strong wind
Strong wind
Strong wind
Fig. 6.1 Fig. 6.2
Step 2: Install UIFoutdoor unit
Fix the outdoor unit with anchor bolts (M10)
> 60cm/23.6JO
Fix with bolts
CAUTION
U Be sure to remove any obstacles that
may block air circulation.
U Make sure you refer to Mength
Tpecifications to ensure there is
enoughroom for installation and
maintenance.
Fig. 6.3