PERFORMANCE DATA SHEET
Water Filtration System
Model P9WB2L/P9RFWB2L Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI Standards 42, 53, and 401.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to
22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
Use replacement filter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B.
2014 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices
are subject to change without notice.
The filter monitor system measures the amount of water that passes
through the filter and alerts you to replace the filter.
Style 1 - When Order Filter is illuminated yellow order a new filter.
When Replace Filter is illuminated red, it is recommended that you
replace the filter.
Style 2 - Press OPTIONS or SETTINGS and select Filter Status to
check the status of your water filter. When the filter status shows
10% remaining, order a new filter. When the filter status shows 0%
remaining, it is recommended that you replace the filter.
Style 3 - Press FILTER STATUS to check the status of your water
filter. When the filter status shows 10% remaining, order a new filter.
When the filter status shows 0% remaining, it is recommended that
you replace the filter.
After changing the water filter, flush the water system. See “Water
and Ice Dispensers.”
These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
EPA Est. No. 082047-TWN-001
Refer to the “Warranty” section for the Manufacturer’s name and
telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against
NSF/ANSI Standard 42, Standard 53, and Standard 401 for
the reduction of substances as listed below.
Substance Reduction Aesthetic Effects Maximum Permissable
Product Water Concentration
Influent Challenge Concentration Average% Reduction
Chlorine Taste/Odor
Particulate Class I
*
50% reduction
85% reduction
2.0 mg/L ± 10%
At least 10,000 particles/mL
97.0%
>99.9%
Contaminant Reduction Maximum Permissable
Product Water Concentration
Influent Challenge Concentration Average%Reduction
Lead: @ pH 6.5 / @ pH 8.5 0.010 mg/L 0.15 mg/L± 10% >99.3% / 98.6%
Benzene 0.005 mg/L 0.015 mg/L ± 10% 93.8%
p-Dichlorobenzene 0.075 mg/L 0.225 mg/L ± 10% 99.8%
Carbofuran 0.040 mg/L 0.08 mg/L ± 10% 81.9%
Toxaphene 0.003 mg/L 0.015 ± 10% >95%
Atrazine 0.003 mg/L 0.009 mg/L ± 10% 87.0%
Asbestos 99% 10
7
to 10
8
fibers/L
††
>99%
Live Cysts
Turbidity
99.95%
0.5 NTU
50,000/L min.
11 NTU ± 10%
>99.99%
96.9%
Lindane 0.0002 mg/L 0.002 ± 10% >99.2%
Tetrachloroethylene 0.005 mg/L 0.015 mg/L ± 10% >96.6%
O-Dichlorobenzene 0.60 mg/L 1.8 mg/L ± 10% 92.3%
Ethylbenzene 0.70 mg/L 2.1 mg/L ± 10% 86.9%
1,2,4-Trichlorobenzene 0.07 mg/L 0.210 mg/L ± 10% >99.8%
2,4 - D 0.07 mg/L 0.210 mg/L ± 10% 88.5%
Styrene 0.1 mg/L 2.0 mg/L ± 10% 99.6%
Toluene 1.0 mg/L 3.0 mg/L ± 10% 93.5%
Endrin 0.002 mg/L 0.006 mg/L ± 10% 81.7%
Atenolol 30 ng/L 200 ± 20% 95.7%
Trimethoprim 20 ng/L 140 ± 20% 96.1%
Linuron 20 ng/L 140 ± 20% 96.3%
Estrone 20 ng/L 140 ± 20% 95.3%
Nonylphenol 200 ng/L 1400 ± 20% 95.5%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.75 gpm (2.84 L/min.) @ 60 psi
*
††
Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.