8. Chimney Fire
In the event of a chimney re
• Have the chimney and adjacent structure inspected by
qualied professionals. Hearth & Home Technologies
recommends that NFI or CSIA certied professionals,
or technicians under the direction of certified
professionals, conduct a minimum of an NFPA 211
Level 2 inspection of the chimney.
• Replace components of the chimney and replace
as specied by the professionals.
• Ensure all joints are properly engaged and the
chimney is properly secured.
WARNING! Risk of Fire! A chimney re can perma-
nently damage your chimney system. Failure to re-
place damaged components and make proper repairs
can cause a structure re.
7. Over-Firing Your Fireplace
WARNING! Risk of Fire! Do not over-re.
Over-firing may ignite creosote or will damage the
replace and chimney.
Symptoms of over-ring may include one or more of the
following:
• chimney connector or replace glowing
• roaring, rumbling noises
• loud cracking or banging sounds
• metal warping
• chimney re
To prevent over-ring your replace. DO NOT:
• use ammable liquids
• overload with wood
• burn trash or large amounts of scrap lumber
• permit too much air to the re
2. Grate
This replace is designed to be used with the supplied
grate or one approved by HHT.
WARNING! Risk of Fire! Use only the factory-sup-
plied integral grate.
• Keeps logs in place.
• Allows proper air circulation around the re.
3. Refractory
The refractory is supplied to contain heat and provide
an attractive interior.
It will break down over time and will need occasional
replacement. Small hairline cracks and discoloration
are normal and do not affect its safety.
WARNING! Risk of Fire! DO NOT burn replace with-
out refractory. Use only refractory supplied by Hearth &
Home Technologies.
4. Firescreen
The rescreen is provided to control sparks. Keep it
closed when the replace in use.
WARNING! Risk of Fire or Burns!
• Screen will not prevent burning materials from falling
out.
• Screen pulls or handles may be hot.
5. Flue Damper
The ue damper must be in the fully opened position
during operation of the replace.
WARNING! Risk of Fire and Asphyxiation! Open
damper prior to operating replace. A closed damper
overres the replace and spills smoke and ames
into the room.
6. Glass Doors
Glass doors are optional.
WARNING! Risk of Fire! Install ONLY doors approved
by Hearth & Home Technologies.
WARNING! Risk of Fire and Smoke! Fireplace
equipped with doors should be operated only with
doors fully open or doors fully closed. If doors are left
partly open, gas and ame may be drawn out of the
replace opening.