PROBLEM
Burners click continuously.
Surface burners do not light.
Uneven or too high flame,
burner is hard to light.
Uneven flame - LP/bottled
gas users.
POSSIBLE CAUSE(S)
Knob(s) are in the "light" position.
Gas is turned off.
Unit is not hooked up to gas supply.
Plug is not completely inserted into
outlet.
Circuit breaker is tripped.
Burner ports are clogged.
Misaligned burner cap.
Ignitor is wet, damaged or dirty.
Burner ports are clogged.
Misaligned burner cap.
Burner cap is wet.
LP conversion not completed
properly.
SOLUTION(S)
Turn knob(s) to "OFF" position or to desired
flame setting,
Make sure the gas shut-off valve is in the
ON position and the gas supply to the
house is not shut off.
Call gas company.
Incorrect house wiring. Check the power
supply. Verify that the unit is grounded with
the correct polarity. Make sure the unit is
plugged in.
Check circuit breaker and reset if
necessary. Check and/or replace fuse.
With the cooktop turned off and coot,
remove burner caps. Use a stiff nylon
bristle toothbrush to push debris through
burner ports.
Verify that burner caps are properly
3ositioned over burners.
Check ignitor for moisture. If wet, allow to
air dry before using. Check for burned-on
food or grease. See cleaning
recommendations, page 23. Burner will
not light if ignitor is wet, damaged or
dirty.
With the cooktop turned off and coot,
remove burner caps. Use a stiff nylon
bristle toothbrush to dislodge debris.
Verify that burner caps are properly
positioned over burners.
Turn off burner, coot and dry burner cap
and burner base throroughty.
Call service.