INS TALLING THE DUCT WORK
(DUCTED HOODS ONLY)
Caution: To reduce the risk of fire, metal ductwork is preferred.
1. Decide where the ductwork
will run between the hood
and the outside.
2. A straight, short duct run will
allow the hood to perform
most efficiently.
3. Long duct runs, elbows, and
transitions will reduce the
performance of the hood.
Use as few of them as
possible. Larger ducting may
be required for best performance with longer duct runs.
4. The air must not be discharge into a flue that is used for exhausting
fumes from appliances burning gas or other fuels" "Regulations
concerning the discharge of air must be fulfilled.
5. Install a wall or roof cap. Connect round metal ductwork to cap and work
back towards hood location. Use duct tape to seal the joints between
ductwork sections.
ELECTRICAL INSTALLATION
Electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards. This range hood must be properly
grounded. Turn off electrical power at the switchboard before wiring.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons to avoid a hazard.