7
Clamp
Clamp
Bare metal
Bare
metal
Insulating
device
4 AWG wire
(minimum)
Insulated Pipe Jumper
4-Wire Electrical Connection
1. Separate the wires coming out of the oven conduit.
2. Connect the oven conduit white wire to the junction box white
(neutral) supply wire.
3. Connect the oven conduit black wire to the junction box black
(L1) supply wire.
4. Connect the oven conduit red wire to the junction box red (L2)
supply wire.
5. Connect the oven conduit green wire to the junction box
green (ground) wire.
3-Wire Electrical Connection (if allowed)
WARNING
Do not connect the green appliance conduit wire to the neutral
(white) junction box wire unless local building codes permit.
1. Separate the wires leaving the appliance conduit.
2. Connect the oven conduit green and the white wires to the
junction box white (neutral) supply wire.
3. Connect the black wire from the appliance conduit to the
junction box black (L1) supply wire.
4. Connect the red wire from the appliance conduit to the junc-
tion box red (L2) supply wire.
3-Wire Electrical Connection w/External
Ground (if allowed)
WARNING
Do not ground the oven to a gas-supply pipe or hot-water pipe.
If connecting the ground wire to a grounded cold-water pipe, use a sep-
arate copper grounding wire (#10 minimum) and a clamp with an exter-
nal grounding screw. This pipe must have metal continuity to electrical
ground, interrupted by insulation. (Insulating materials must be jumped
with a minimum 4 AWG wire to establish continuity to ground.)
NOTE
If the junction box is properly grounded by a licensed electrician, the
green (ground) wire from the appliance conduit may be connected to
the junction box using a loop terminal.
1. Separate the wires coming out of the oven conduit.
2. Connect the oven conduit white wire to the junction box white
(neutral) supply wire.
3. Connect the oven conduit black wire to the junction box black
(L1) supply wire.
4. Connect the oven conduit red wire to the junction box red (L2)
supply wire.
5. Connect the oven conduit green wire to a grounded cold-water
pipe; jumper any insulating material with a length of #4 copper
wire. Securely
clamp the wire to bare metal at both ends.
Green
Red
Red
Wire nut
(4 places)
White
White
Black
Black
Conduit to oven
Incoming power
Green
Junction box
Red
Red
Green
White
White
Black
Black
Wire nut
(3 places)
Conduit to oven
Junction box
Incoming power
INSTALLATION INSTRUCTIONS