Your safety and the safety of others are very important.
This safety Alert symbol warns you from potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol with the word “WARNING” or “CAUTION”. These words mean:
WARNING
Indicates a hazard which, if not avoided, can result in severe personal injury or death and damage to
product or other property.
CAUTION
Indicates a hazard which, if not avoided, can result in personal injury and damage to product or other property.
NOTICE
Indicates property damage can occur if instructions are not followed.
Model Plug Type
WS08, WS10, WS12 NEMA No. 5-15P 125 V-15 AMP
NEMA No. 6-15P 250
V
-15 AMP
WS10, WS12, WS15
WE10, WE12, WE15,
WY09, WY12
NEMA No. 6-20P 250V-20 AMP
Electrical Data
Electrical Shock Hazard
WARNING
Make sure your electrical receptacle has the same
configuration as your air conditioner’s plug. If
different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Circuit Rating,
Breaker or Time
Delay Fuse
Safety Precautions
Never use an extension cord
Your Friedrich room air conditioner is equipped with a three-
prong (grounded) plug for your protection against shock hazards
and should be plugged directly into a properly grounded three-
prong receptacle. If you have a two-prong receptacle you will
need to have the circuit replaced by a certified electrician with a
grounded circuit that meets all national and local codes and
ordinances. Under no circumstances should you remove the
ground prong from the plug. You must use the three-prong plug
furnished with the air conditioner.
NEVER CUT OR REMOVE THE GROUNDING PRONG FROM THE
P
L
UG.
Power cord information
All Friedrich room air conditioners are shipped from the
factory with a Leakage Current Detection Interrupter (LCDI)
equipped power cord. The LCDI device meets the UL and
NEC requirements for cord connected air conditioners
effective August 2004.
To test your power supply cord:
1.
Plug power supply cord into a grounded 3 prong outlet.
2.
Press RESET (See Figure A).
3.
Press TEST (listen for click; Reset button trips and pops out).
4.
Press and release RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready for
operation.
NOTE: LCDI device is not intended to be used as a switch.
Once plugged in the unit will operate normally without the
need to reset the LCDI device.
If the device fails to trip when tested or if the power supply
cord is damaged it must be replaced with a new supply cord
from the manufacturer. We recommend you contact our
Technical Assistance
Line at (800) 541-6645 ext. 845. To
expedite service, please have your model
and serial number
available.
3
TEST
RESET
WARNING
TEST BEFORE EACH USE
1.
PRESS RESET BUTTON
2.
PLUG LDCI INTO POWER
RECEPTACLE
3.
PRESS TEST BUTTON,
RESET BUTTON SHOULD
POP UP
4.
PRESS TEST BUTTON,
FOR USE,
DO NOT USE IF ABOVE TEST
FAILS WHEN GREEN LIGHT
IS ON
RESET
TEST
Figure A
NOTE: Your LCDI device will resemble one of these
illustrations.
We have provided important safety messages in this manual and on your appliance. Always read and obey all safety messages. All safety messages will