Loading ...
Loading ...
124775B HEPA 700 3 Legend Brands, Inc.
2. Remove the prefilter from the filter door and discard.
3. Insert new prefilter into filter door. Ensure that the prefilter is
seated properly on the retention tabs.
4. To replace the HEPA Primary filter, proceed to the next step.
Otherwise, replace filter assembly on to unit and reattach the
four buckles.
Replacing the HEPA Primary Filter
IMPORTANT: Performance is reduced when a non-Legend
Brands primary filter is installed. For maximum filtration
performance, use only Legend Brands filters. Do not clean
and reuse the HEPA filter. Always replace the prefilter when
replacing the HEPA filter.
1. Lay unit on its back and release the four (4) buckles. Lift
off the filter door.
2. Remove the prefilter from the filter door and discard.
3. Release the two locking tabs and lift out primary filter
element. Discard used filter.
4. Replace HEPA primary filter, handling it with care, as filter
is easily damaged. Do not use a filter that is damaged.
5. Place new prefilter(s) in filter door. Replace filter cover and
lock the four buckles securely.
Before each use
Inspect the electrical cord for damage, and do not use the unit
if you find any fraying, cuts, etc. Contact your local distributor
for service.
As Needed
Clean exterior of housing and inside the filter compartment.
Ensure housing is completely dry before reassembling. Do not
apply liquids to control panel or to any electrical components.
When using the HEPA 700 for remediation or in
sensitive environments:
Wear NIOSH-approved protective gear when changing
filters.
Change both filters after every remediation job.
Dispose of used filters according to local regulations.
Replace both the prefilter and HEPA filter to prevent
cross-contamination.
Clean the unit thoroughly (vacuum and damp wipe per
IICRC S520, 10.11) before removing it from the
containment area to avoid cross-contamination. Let the
unit dry before installing clean filters.
For parts and service contact your local distributor or Legend Brands: Live Chat - Info.legendbrands.com | Email:
Filter Options
Air Filtration Applications:
Prefilter(s)
Removes larger
particulates protects
primary filter
Specialty Prefilter
Carbon removes
VOCs and odors
Primary filter (HEPA)
Removes fine particulate
down to .3 microns
Water loss air filtration and mold
remediation*
Standard air scrubbing. For high particle
loads, such as construction or remodeling sites.
2-in. MERV 8 Pleated
Paper Filter
#125026 (6 pk.)
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
Odor control and air filtration. For removing
volatile organic compounds (VOCs), fumes from
paint and paint thinners, and many other
noxious odors, eg, from food, sewage, etc.
Smoke particulate and odor removal. Paper
prefilter and HEPA filter remove particulates
and carbon filter adsorbs odors.
1-in. MERV 8 Pleated
Paper Filter
#125029 (12 pk.)
1-in. Activated
Carbon Filter
#125027 (4 pk.)
HEPA Filter
#124966 (1 pk.)
#125028 (8 pk.)
SPECIFICATIONS
Model
HEPA 700 (#125105)
Airflow
Variable to 700 CFM | 1189 CMH
Static pressure
3.0 in. (H
2
O) | 747 Pa
Weight
42.0 lbs. | 19.1 kg
Dimensions
(H × D × W)
22.8 × 17.0 × 25.9 in.
57.9 × 43.3 × 65.9 cm
Amps/Power
1.5 - 3.0 amps, 115v, 60 Hz, 350w
Power cord
25 ft. | 7.6 m
Duct size
14 in. | 35.6 cm
Construction
Injection-molded plastic housing
Xactimate
WTRNAFAN>
Safety
ETL listed to UL 507 and CSA C22.2 No. 113
Specifications are subject to change without notice. Some values
may be approximate.
Loading ...
Loading ...
Loading ...