APPENDIX A:
Input Sensitivity Level Setting
Following the directions below will allow the
installer to adjust the input sensitivity of each
amplifier channel pair simply and easily in just a
few minutes using equipment which is commonly
available in installation bays.
Necessary Equipment
• Digital AC Voltmeter
CD with a sine-wave test tone recorded at
0 dB reference level in the frequency range
to be amplified for that set of channels
(50 Hz for subwoofer channels, 1 kHz for a
midrange application). Do not use attenuated
test tones (-10 dB, -20 dB, etc.).
The Nine-Step Procedure
1) Disconnect the speaker(s) from the
amplifier’s speaker output connectors.
2) Turn off all processing (bass/treble, loudness,
EQ, etc.) on the source unit, processors (if
used) and amplifier. Set the fader control
to center position and the subwoofer level
control to 3/4 of maximum (if used to feed the
XD300/1v2).
3) Switch the “Input Voltage” switch to “Low
and turn the amplifiers “Input Sens.” control
all the way down.
4) Set the source unit volume to 3/4 of full
volume. This will allow for reasonable gain
overlap with moderate clipping at full volume.
5) Using the chart on this page, determine the target
voltage for input sensitivity adjustment according
to the nominal impedance of the speaker system
connected to the amplifier outputs.
6) Verify that you have disconnected the speakers
before proceeding. Play a track with an
appropriate sine wave (within the frequency
range to be amplified by the XD300/1v2) at 3/4
source unit volume.
7) Connect the AC voltmeter to the speaker
output connectors of the amplifier. Make sure
you test the voltage at the correct connectors
(+ and –).
8) Increase the Input Sens. control until the
target voltage is observed with the voltmeter.
9) Once you have adjusted the XD300/1v2 to
its maximum low-distortion output level,
reconnect the speaker(s). The Input Sens.
controls can now be adjusted downward if the
amplifier requires attenuation to achieve the
desired system balance.
Do not increase any Input Sens. setting for
any amplifier channel or channel pair in the
system beyond the maximum level established
during this procedure. Doing so will result in
audible distortion and possible speaker damage.
It will be necessary to re-adjust the
Input Sens. if any equalizer boost is activated
after setting the Input Sens. with this
procedure. This applies to any EQ boost circuit,
including source unit tone controls or EQ
circuits. EQ cuts will not require re-adjustment.
Nom. Impedance Target AC Voltage
4 28.3 V
3 27.4 V
2 24.5 V
1
Not Recommended