RefertoParts List Manual for your compressor. Certain
air compressor models can be operated on a 15 amp
circuit if:
1. Voltage supply to circuit is normal.
2. Circuit is not used to supply any other electrical needs
(lights, appliances, etc.).
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15
amp time delay fuse.
Ifany of the above conditions cannot be met, or ifoperation
of the compressor repeatedly causes interruption of the
power, it may be necessary to operate it from a 20 amp
circuit. It is not necessary to change the cord set.
GROUNDING INSTRUCTIONS
If repairing cord or plug, the grounding wire must be kept
separate from the current-carrying wires. Neverconnectthe
grounding wire to a flat blade plug terminal. The grounding
wire has insulation with an outer surface that isgreen- with
or without yellow stripes.
If these grounding instructions are not completely under-
stood, or if in doubt as to whether the compressor is
properly grounded, have the installation checked by a
qualified electrician.
120 Volt Models
240 Volt Models
White
2OAMP PLUG OUTLET
GROUNDING J _ PIN
PIN
RISKOR ELECTRICAL SHOCK. In the event ofa
shortcircuit, grounding reduces the risk of shock by
providing an escape wire for the electric current.
This air compressor must be properly grounded.
The portable air com pressor is equipped with acord having
a grounding wire with an appropriate grounding plug. The
plug must be used with an outlet that has been installed and
grounded in accordance with all localcodes and ordinances.
The outlet must have the same configuration as the plug.
DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use. Do not use if
there are signs of damage.
IMPROPER GROUNDING CAN RESULTIN ELEC-
TRICAL SHOCK.
Do not modify the plug that has been provided. Ifit
does not fit the available outlet, the correct outlet
should be Installed by aqualified electrican.
Break-in Procedure
Serious damage may result if the following
break-in instructions are not closely followed.
This procedure is required only once, before the air
compressor is put into service.
1. Set the pressure switch OFF/AUTO lever in the
"OFF" position.
2. Plug the power cord into the correct branch circuit
receptacle.
3. Turn the regulator clockwise, opening it fully, to
prevent air pressure build-up in the tank.
4. Move the OFF/AUTO lever to "AUTO". The com-
pressor will start.
5. Run the compressor for 15 minutes. Make sure the
regulator is open and there is no tank pressure build-
up.
6. After 15 minutes, close the regulator by turning it
counterclockwise. The air tank will fill to cut-out
pressure and then the motor will stop.
Refer to "Operating Procedures".